A Simple Paper-Based, Wearable Device for Long Term Sweat Analysis

By LabMedica International staff writers
Posted on 16 Jun 2020
By cleverly manipulating paper geometry, researchers created a paper-based wearable device to collect, transport, and analyze sweat for an extended period.

Sweat can be used to obtain an exact measurement of concentrations of medications in the blood. More...
Furthermore, the concentrations of stress biomarkers (hormones and neurotransmitters) in bodily fluids such as sweat predict the physical and mental state of the individual.

A major problem that has so far restricted the use of wearable paper-based sweat sensors is that sweat contains salt, which, upon evaporation, becomes deposited on the device and interferes with fluid flow. To solve this problem, investigators at North Carolina State University (Raleigh, USA) characterized and analyzed how capillary action and evaporation could cooperatively be used to transport and process a sweat-like fluid containing dissolved salts and model analytes.

The investigators postulated that the joint action of capillary wicking and evaporation would sustain continuous and long-term withdrawal of the sweat-like fluid. In the laboratory they then demonstrated that paper strips of controlled geometry could passively pump fluid for sensing purposes for long duration. Thus, non-invasive osmotic extraction combined with paper microfluidics and evaporative disposal enabled sweat collection and monitoring for periods exceeding 10 days. Since the process was driven by the liquid wicking through paper, the device did not require an external power source.

The investigators also demonstrated that the salt film deposited at the evaporation pad would eventually lead to cessation of the process but at the same time would preserve a record of analytes that could be used for long-term biomarker monitoring in sweat.

"We expected that the flow of the model sweat will be suppressed by the deposition of a salt layer inside the drying pad," said senior author Dr. Orlin Velev, professor of chemical and biomolecular engineering at North Carolina State University. "By following the flow of model sweat, we found, quite surprisingly, that such a simple paper construct can achieve continuous sweat pumping and disposal for very long periods."

The wearable device for sweat analysis was described in the June 9, 2020, online edition of the journal Biomicrofluidics.

Related Links:
North Carolina State University


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Nucleic Acid Extractor System
NEOS-96 XT
Automated Urinalysis Solution
UN-9000
New
Gold Member
Blood-Based Protein Biomarker Solution for Alzheimer's Disease
BG-DTi2000.
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: The findings point to readily accessible blood biomarkers that could support disability risk stratification in geriatric care (Image Credit: Adobe Stock)

Blood Test Markers Could Help Identify Older Adults at Risk of Disability

Maintaining independence into very old age is a growing public health challenge as Japan’s population rapidly ages. Nearly 60% of Japanese adults aged 85 years and older already receive support through... Read more

Pathology

view channel
Image: TRUECAM automatically eliminates ambiguous or uninformative regions in whole-slide pathology images, enhancing the reliability of diagnostic analysis. (Photo courtesy of PolyU)

AI-Pathologist Framework Improves Accuracy and Reliability in Cancer Diagnosis

Ensuring reliable cancer diagnosis from digital pathology remains a critical challenge as clinical decisions rely on accurate slide interpretation. While artificial intelligence (AI) has accelerated whole-slide... Read more

Industry

view channel
Image: HealthTab will distribute the Abbott Afinion 2 Analyzer to NHS-linked pharmacies for hemoglobin A1c (HbA1c) and lipid profile testing. (Photo courtesy of Abbott)

New Collaboration Expands Point-of-Care Testing Across UK Community Pharmacies

HealthTab, a wholly owned subsidiary of Avricore Health, has entered a formal collaboration agreement with Abbott to supply and distribute Abbott’s point-of-care testing products in the UK through the... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.