We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Various Factors Influence Cardiac Troponin Concentrations

By LabMedica International staff writers
Posted on 14 Sep 2017
Print article
Image: The ARCHITECT i2000SR immunoassay analyzer (Photo courtesy of Abbott Laboratories).
Image: The ARCHITECT i2000SR immunoassay analyzer (Photo courtesy of Abbott Laboratories).
Cardiovascular diseases are the second most common cause of death in Japan, and the number of new cases is continuously growing. Among the cardiovascular diseases, one-third is attributed to ischemic heart diseases including acute myocardial infarction (AMI).

Cardiac troponin I is a protein that is specifically expressed in cardiomyocytes and is eluted in the blood when cardiomyocytes are injured such as by ischemia. Due to its specificity, cardiac troponin I has become one of the most reliable biomarkers for the diagnosis of AMI.

Scientists at the Japanese Red Cross Medical Center (Tokyo, Japan) and their colleagues enrolled a total of 698 apparently healthy individuals (385 females and 313 males) between the ages of 23 and 86 who visited the Medical Center for a health checkup from January through April in 2014 were included in this study.

The team performed routine biochemistry tests on a BioMajesty JCA-BM6070 clinical biochemistry analyzer that included the assays for aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma glutamyl transferase (GGT), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), creatinine (Cre), hemoglobin A1c (HbA1c), and lactate dehydrogenase (LDH). Serum samples were used for the measurement of all the assays except for HbA1c, which was measured with whole-blood samples.

The Abbott Laboratories’ STAT high-sensitive troponin I (hsTnI) was performed for the measurement of cardiac troponin I on Architect i2000. The limit of detection (LoD) of the assay was 1.9 pg/mL, the lowest concentration where 10% coefficient of variation (CV) was supported was 4.7 pg/mL and the overall 99th percentile was 26.2 pg/mL. The CardioPhase high-sensitive C-reactive protein (hsCRP) tests were performed for the measurement of CRP. The limit of detection (LoD) of the assay was 0.175 mg/L, the CV was 7.6% at 0.410 mg/L and the reference value was 3 mg/L.

The scientists found that the 99th percentile of the hsTnI in the overall population was 22.5 pg/mL, 17.7 pg/mL for females and 30.6 pg/mL for males. The median of the hsTnI in the overall population was 3.2 pg/mL, 2.6 pg/mL for females and 4.0 pg/mL for males. The age and gender had a significant influence on these values. The troponin I level also showed significant associations with the body mass index (BMI), the gamma glutamyl transferase (GGT), lactate dehydrogenase (LDH), estimated glomerular filtration rate (eGFR), and cardiac abnormalities by electrocardiography (ECG), but not with the high-sensitive C-reactive protein (hsCRP) level.

The authors concluded that the 99th percentiles of the troponin I measured in the general population in Japan were comparable as the ones derived in the USA, Germany, and Singapore. The troponin I level was dependent on the gender, age, BMI, and cardiac abnormalities found by electrocardiogram (ECG) but not by the hsCRP level. The study was published on August 1, 2017, in the Journal of Clinical Laboratory Analysis.

Related Links:
Japanese Red Cross Medical Center

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.