Chip-Based Technology Enables Direct Detection of Ebolavirus

By LabMedica International staff writers
Posted on 06 Oct 2015
A hybrid device has been developed that integrates a microfluidic chip for sample preparation and an optofluidic chip for optical detection of individual molecules of viral ribonucleic acid (RNA). More...


The current gold standard for Ebolavirus detection relies on a method called polymerase chain reaction (PCR) to amplify the virus's genetic material for detection. Because PCR works on DNA molecules and Ebola is an RNA virus, the reverse transcriptase enzyme is used to make DNA copies of the viral RNA prior to PCR amplification and detection.

Scientists at The University of California, Santa Cruz (CA, USA) have developed chip-based technology for reliable detection of Ebolavirus and other viral pathogens. The system uses direct optical detection of viral molecules and can be integrated into a simple, portable instrument for use in field situations where rapid, accurate detection of Ebola infections is needed to control outbreaks. The system combines two small chips, a microfluidic chip for sample preparation and an optofluidic chip for optical detection.

The microfluidic devise is made of a silicon-based polymer, polydimethylsiloxane (PDMS), and has microvalves and fluidic channels to transport the sample between nodes for various sample preparation steps. The targeted molecules, in this case, Ebolavirus RNA are isolated by binding to a matching sequence of synthetic DNA, called an oligonucleotide, attached to magnetic microbeads. The microbeads are collected with a magnet, nontarget biomolecules are washed off, and the bound targets are then released by heating, labeled with fluorescent markers, and transferred to the optofluidic chip for optical detection.

In laboratory tests, the system provided sensitive detection of Ebolavirus while giving no positive counts in tests with two related viruses, Sudan ebolavirus and Marburgvirus. Testing with different concentrations of Ebolavirus demonstrated accurate quantification of the virus over six orders of magnitude. Adding a "preconcentration" step during sample processing on the microfluidic chip extended the limit of detection well beyond that achieved by other chip-based approaches, covering a range comparable to PCR analysis.

Holger Schmidt, PhD, a professor of Optoelectronics and senior author of the study, said, “Compared to our system, PCR detection is more complex and requires a laboratory setting. We're detecting the nucleic acids directly, and we achieve a comparable limit of detection to PCR and excellent specificity. The measurements were taken at clinical concentrations covering the entire range of what would be seen in an infected person.” The study was published on September 25, 2015, in the journal Nature Scientific Reports.

Related Links:

The University of California, Santa Cruz  



Gold Member
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Collection and Transport System
PurSafe Plus®
Gold Member
Automatic Hematology Analyzer
DH-800 Series
Urine Chemistry Control
Dropper Urine Chemistry Control
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: New evidence shows viscoelastic testing can improve assessment of blood clotting during postpartum hemorrhage (Photo courtesy of 123RF)

Viscoelastic Testing Could Improve Treatment of Maternal Hemorrhage

Postpartum hemorrhage, severe bleeding after childbirth, remains one of the leading causes of maternal mortality worldwide, yet many of these deaths are preventable. Standard care can be hindered by delays... Read more

Immunology

view channel
Image: When assessing the same lung biopsy sample, research shows that only 18% of pathologists will agree on a TCMR diagnosis (Photo courtesy of Thermo Fisher)

Molecular Microscope Diagnostic System Assesses Lung Transplant Rejection

Lung transplant recipients face a significant risk of rejection and often require routine biopsies to monitor graft health, yet assessing the same biopsy sample can be highly inconsistent among pathologists.... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.