Chip-Based Technology Enables Direct Detection of Ebolavirus

By LabMedica International staff writers
Posted on 06 Oct 2015
A hybrid device has been developed that integrates a microfluidic chip for sample preparation and an optofluidic chip for optical detection of individual molecules of viral ribonucleic acid (RNA). More...


The current gold standard for Ebolavirus detection relies on a method called polymerase chain reaction (PCR) to amplify the virus's genetic material for detection. Because PCR works on DNA molecules and Ebola is an RNA virus, the reverse transcriptase enzyme is used to make DNA copies of the viral RNA prior to PCR amplification and detection.

Scientists at The University of California, Santa Cruz (CA, USA) have developed chip-based technology for reliable detection of Ebolavirus and other viral pathogens. The system uses direct optical detection of viral molecules and can be integrated into a simple, portable instrument for use in field situations where rapid, accurate detection of Ebola infections is needed to control outbreaks. The system combines two small chips, a microfluidic chip for sample preparation and an optofluidic chip for optical detection.

The microfluidic devise is made of a silicon-based polymer, polydimethylsiloxane (PDMS), and has microvalves and fluidic channels to transport the sample between nodes for various sample preparation steps. The targeted molecules, in this case, Ebolavirus RNA are isolated by binding to a matching sequence of synthetic DNA, called an oligonucleotide, attached to magnetic microbeads. The microbeads are collected with a magnet, nontarget biomolecules are washed off, and the bound targets are then released by heating, labeled with fluorescent markers, and transferred to the optofluidic chip for optical detection.

In laboratory tests, the system provided sensitive detection of Ebolavirus while giving no positive counts in tests with two related viruses, Sudan ebolavirus and Marburgvirus. Testing with different concentrations of Ebolavirus demonstrated accurate quantification of the virus over six orders of magnitude. Adding a "preconcentration" step during sample processing on the microfluidic chip extended the limit of detection well beyond that achieved by other chip-based approaches, covering a range comparable to PCR analysis.

Holger Schmidt, PhD, a professor of Optoelectronics and senior author of the study, said, “Compared to our system, PCR detection is more complex and requires a laboratory setting. We're detecting the nucleic acids directly, and we achieve a comparable limit of detection to PCR and excellent specificity. The measurements were taken at clinical concentrations covering the entire range of what would be seen in an infected person.” The study was published on September 25, 2015, in the journal Nature Scientific Reports.

Related Links:

The University of California, Santa Cruz  



Gold Member
Blood Gas Analyzer
Stat Profile pHOx
Collection and Transport System
PurSafe Plus®
New
Automated Chemiluminescence Immunoassay Analyzer
MS-i3080
New
Blood Glucose Test Strip
AutoSense Test
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The nanotechnology-based liquid biopsy test could identify cancer at its early stages (Photo courtesy of 123RF)

2-Hour Cancer Blood Test to Transform Tumor Detection

Glioblastoma and other aggressive cancers remain difficult to control largely because tumors can recur after treatment. Current diagnostic methods, such as invasive biopsies or expensive liquid biopsies,... Read more

Hematology

view channel
Image: New research points to protecting blood during radiation therapy (Photo courtesy of 123RF)

Pioneering Model Measures Radiation Exposure in Blood for Precise Cancer Treatments

Scientists have long focused on protecting organs near tumors during radiotherapy, but blood — a vital, circulating tissue — has largely been excluded from dose calculations. Each blood cell passing through... Read more

Pathology

view channel
Image: An adult fibrosarcoma case report has shown the importance of early diagnosis and targeted therapy (Photo courtesy of Sultana and Sailaja/Oncoscience)

Accurate Pathological Analysis Improves Treatment Outcomes for Adult Fibrosarcoma

Adult fibrosarcoma is a rare and highly aggressive malignancy that develops in connective tissue and often affects the limbs, trunk, or head and neck region. Diagnosis is complex because tumors can mimic... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.