Posted on 26 Oct 2014
A novel nanotechnology-based prototype device can detect pathogens such as Ebola and other hemorrhagic fever viruses – quickly and on-site.

The novel device is being developed by a research team led by Boston University's (Boston, MA, USA) Selim Ünlü, professor of biomedical engineering, and John Connor, professor of medical microbiology. More...
Conventional fluorescent label-based virus detection methods require expensive lab equipment, significant sample preparation, transport and processing times, and extensive user training. A solution in pathogen diagnostics, and thereby also treatment and containment, may come from this device—a rapid, label-free, chip-scale photonic system that can provide affordable, simple, accurate on-site detection, also in resource-limited countries. A potentially game-changing technology, the device identifies individual viruses based on size variations resulting from distinct genome lengths and other factors.

The first demonstration of the concept, reported in 2010 and developed by a group led by Prof. Ünlü in collaboration with Bennett Goldberg, professor of physics at BU, showed the ability to pinpoint and size single H1N1 virus particles. Now, after 4 years of refining the instrumentation with the collaboration of Prof. Connor's group and researchers at the University of Texas Medical Branch, the team has demonstrated simultaneous detection of multiple viruses in blood serum samples—including viruses genetically modified to mimic the behavior of Ebolavirus and the Marburgvirus.

“Others have developed different label-free systems, but none have been nearly as successful in detecting nanoscale viral particles in complex media,” says Prof. Ünlü, referring to typical (e.g., unprocessed blood) samples that may have a mix of viruses, bacteria, and proteins. He added, “Leveraging expertise in optical biosensors and hemorrhagic fever diseases, our collaborative research effort has produced a highly sensitive device.” Also, the system requires little to no sample preparation time and delivers answers in about 1 hour. “By minimizing sample preparation and handling, our system can reduce potential exposure to health care workers,” said Prof. Connor, “And by looking for multiple viruses at the same time, patients can be diagnosed much more effectively.”

The shoebox-sized, battery-operated prototype – the single particle - interferometric reflectance imaging sensor (SP-IRIS) – detects by shining light from multicolor LED sources on viral nanoparticles trapped onto the sensor surface by a coating of virus-specific antibodies. Interference of light reflected from the surface is modified by the presence of the particles, producing a distinct signal that reveals the size and shape of each particle. The system is capable of high-throughput as the sensor surface is very large and can capture the telltale responses of up to a million nanoparticles.

In collaboration with BD Technologies (Research Triangle Park, NC, USA) and the start-up NexGen Arrays (Boston, MA, USA), the team is now working on making SP-IRIS more robust, field-ready, and fast — ideally delivering answers within 30 minutes—through further technology development and preclinical trials. SP-IRIS devices are now being tested in several labs, including a Biosafety Level-4 (BSL-4) lab at the University of Texas Medical Branch equipped to work with hemorrhagic viruses. Other tests will be conducted at BU’s NEIDL once the facility is BSL-4 approved. Based on the current rate of progress, the instrument could be ready to enter the field in 5 years.

The research, by Daaboul GG et al., appeared in the journal ACS Nano, May, 2014.

Related Links:

Boston University
BU National Emerging Infectious Diseases Laboratories (NEIDL) 
NexGen Arrays 



New
Gold Member
Automatic Hematology Analyzer
CF9600
POC Helicobacter Pylori Test Kit
Hepy Urease Test
New
Superspeed Centrifuges
LYNX 4000 and 6000
New
ACR Urine Test
On Call MultiPro ACR
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Copyright © 2000-2026 Globetech Media. All rights reserved.