We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Sekisui Diagnostics

Download Mobile App




Biosensing Platform Detects Bacterial Pneumonia

By LabMedica International staff writers
Posted on 05 Jan 2011
A technique has been developed that will diagnose and differentiate the organisms that cause pneumonia using nanotechnology.

The method combined the existing technology of surface-enhanced Raman spectroscopy (SERS) with silver nanorods to identify different strains of Mycoplasma pneumoniae. More...
Raman spectroscopy works by detecting spectral signatures of a near-infrared laser as it scatters off a biological specimen.

Scientists at the University of Georgia (UGA; Athens, GA, USA), were able to detect and differentiate M. pneumoniae strains from throat swabs. They equated the nanorod array system to a brush with densely packed bristles, where each of the tiny silver rods extends out at a specific angle. The sample, such as bacteria from a throat swab, penetrates among the bristles, where the spectral signature produced by the laser is amplified and then analyzed by a computer program.

Clinical throat swab samples, collected from the University of Alabama (Birmingham, AL, USA), were processed by extraction and subsequently tested by polymerase chain reaction (PCR). Three M. pneumoniae strains were reproducibly differentiated by nanorod-SERS (NA-SERS), with 95%–100% specificity and 94%–100% sensitivity, and with a lower detection limit exceeding standard PCR. In addition, NA-SERS correctly classified with greater than 97% accuracy, 10 true clinical throat swab samples previously established by real-time PCR and culture to be positive or negative for M. pneumoniae.

Duncan C. Krause, PhD, a professor of microbiology at UGA, said, "If you can make a positive identification from a 10-minute test, then appropriate antibiotics can be prescribed, limiting both the consequences in that patient and the likelihood that it will spread to others. The device can be reduced to a size that could fit in a briefcase, although testing is currently done only in a laboratory setting. Our hope is that when we begin to explore the capabilities of this technology, it can be applied in point-of-care testing. Then the impact becomes truly significant."

Infections due to M. pneumoniae are very common yet difficult to diagnose. The bacterium is a major cause of respiratory disease in humans accounting for 20% of all community-acquired pneumonia and the leading cause of pneumonia in older children and young adults. It can cause permanent damage to the lungs if not diagnosed promptly. A delay in diagnosis extends the likelihood for complications as well as continued transmission to the community. The study was published online December 2010 in PLoS One.

Related Links:

University of Georgia
University of Alabama



Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Electrolyte Analyzer
CBS-4000 (CBS-400)
Platinum Member
Integrated Biochemical & Immunological System
Biolumi CX Solution X10+C10
Gold Member
Platelet Function Analyzer
PL-12
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image Credit: 123RF

Screening After Pneumococcal Disease May Reveal Undiagnosed Blood Cancer or Immune Disorders

Severe pneumococcal disease requiring hospitalization often presents as pneumonia, particularly in older adults and people with cancer or compromised immune function. Because M protein testing and antibody... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image

Collaboration Combines AI Cognitive Assessment and RNA Blood Testing for Earlier Alzheimer’s Detection

Alzheimer’s disease is often identified only after substantial neurodegeneration, partly because current diagnostic pathways are fragmented and difficult to scale. As treatment shifts toward earlier intervention,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.