We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

QUIDEL

Develops, manufactures and markets rapid diagnostic tests at the point-ofcare (POC) that focus on infectious diseases... read more Featured Products: More products

Download Mobile App




Rh Alloimmunization Explored in Chronically Transfused Thalassemia Patients

By LabMedica International staff writers
Posted on 01 Mar 2021
Print article
Image: Schematic diagram of Rh alloimmunization in chronically transfused patients with thalassemia receiving RhD, C, E, and K matched transfusions (Photo courtesy of The Children’s Hospital of Philadelphia).
Image: Schematic diagram of Rh alloimmunization in chronically transfused patients with thalassemia receiving RhD, C, E, and K matched transfusions (Photo courtesy of The Children’s Hospital of Philadelphia).
Chronic life-long transfusions are often required for patients with severe thalassemia to provide normal red blood cells and to suppress the patients’ own ineffective erythropoiesis. Cumulative exposure increases the risk for red cell alloimmunization and subsequent delayed hemolytic transfusion reactions (DHTRs).

The prevalence of alloimmunization among patients with thalassemia ranges from 3% to 42%, with most antibodies directed against the Rh system. The Rh blood group system is not only the most immunogenic following ABO, but it is highly complex with more than 50 serologically defined antigens and more than 500 RHD and RHCE alleles identified.

Medical Scientists at The Children’s Hospital of Philadelphia (Philadelphia, PA, USA) examined retrospectively Rh antibodies among 40 chronically transfused patients (Asian, White, African Americans, Indian, Middle Eastern) with thalassemia receiving a mean of 174 serologic prophylactic RhD, C, E, and K matched red cell units. They examined the patients’ RH genotype, as well as donor race and Rh phenotypes over three transfusion events preceding antibody detection.

A 3-cell antibody screen was performed before each transfusion or when a new antibody or DHTR was suspected. In 2003, antibody identification transitioned from tube method to a gel-based method (Ortho Clinical Diagnostics, Raritan, NJ, USA). Red cell antigen typing was performed by tube method, but starting in 2017, they obtained genotypes via the Human Erythrocyte Antigen BeadChip (Bioarray/Immucor, Warren, NJ, USA). RH genotyping was performed with Bioarray/Immucor’s RHD and RHCE BeadChip arrays, and polymerase chain reaction–based assays.

The investigators detected 18 alloantibodies in 13 of 40 patients (32.5%), with an alloimmunization rate of 0.26 antibodies per 100 units transfused. Thirteen antibodies (72.2%) were directed against Rh (five anti-D, four anti-C, two anti-E, one anti-e, and one anti-V), despite donor phenotypes that confirmed lack of transfusion of D, C, or E antigens to patients lacking the corresponding antigen(s). Ten of 40 patients had an altered RH genotype, but the Rh antibodies were not associated with patients with variant RH. African Americans donors with a known high frequency of RH variants provided 63% of the units transfused in the three visits preceding unexplained anti-Rh detection.

The authors concluded that Rh alloimmunization not explained by the thalassemia patients’ RH genotype or the donors’ serologic phenotype suggests more precise matching is needed, and the role of donor RH genotypes on alloimmunization should be explored. Extending Rh D, C, and E matching to include c and e would result in better-matched units and further minimize Rh alloimmunization. The study was published on February 2, 2021 in the journal Blood Advances.

Related Links:
The Children’s Hospital of Philadelphia
Ortho Clinical Diagnostics
Bioarray/Immucor


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.