B-Type Natriuretic Peptide Sandwich Immunoassay Evaluated

By LabMedica International staff writers
Posted on 23 Apr 2019
Print article
Image: The Minicare I-20 handheld diagnostics platform is designed to detect multiple target molecules at very low concentrations in a single ‘finger-prick’ blood sample, and display the results on a handheld analyzer within minutes (Photo courtesy of Philips Healthcare).
Image: The Minicare I-20 handheld diagnostics platform is designed to detect multiple target molecules at very low concentrations in a single ‘finger-prick’ blood sample, and display the results on a handheld analyzer within minutes (Photo courtesy of Philips Healthcare).
The measurement of circulating natriuretic peptides (NP) is considered to be a useful marker of myocardial function, and international guidelines recommend its use for the diagnosis of patients with heart failure (HF), and in particular ruling out the presence of HF.

Point-of-care B-type natriuretic peptide (BNP) testing with adequate analytical performance has the potential to improve patient flow and provide primary care givers with easy-to-use advanced diagnostic tools in the management of heart failure.

An international team of scientists working with the Medical University of Innsbruck (Innsbruck, Austria) performed a comparison with a lab-testing system using samples from 187 patients. Normal values were determined based on 160 healthy adults, (94 males and 66 females; with 84 aged more than 55 years and 76 aged 55 years or less) with ages ranging from 19 to 70 years. Normal values were determined by testing EDTA whole blood and EDTA plasma samples.

The team compared the Minicare BNP with the Siemens ADVIA Centaur BNP, Alere Triage BNP and Abbott I-STAT BNP. The team tested and compared EDTA whole blood samples (on Minicare, Triage and I-STAT) and corresponding EDTA plasma samples (on Minicare and Centaur) from respectively 187 to 216 individuals with a BNP concentration range as measured using Minicare from 10 to 2,890 ng/L.

The scientists reported that the limit of quantitation (LoQ) in whole blood at 20% and 10% coefficient of variation (CV) was found < 9 ng/L and <30 ng/L respectively without significant differences between EDTA whole blood and EDTA plasma. Total CV was found to be from 6.7% to 9.7% for BNP concentrations between 92.6 and 3,984 ng/L. The sample type comparison study demonstrated correlation coefficients between 0.97 and 0.99 with slopes between 1.03 and 1.09 between the different samples. Method comparison between Minicare BNP and Siemens ADVIA Centaur BNP demonstrated a correlation coefficient of 0.92 with a slope of 1.06. The 97.5% upper reference limit (URL) of a healthy population was calculated to be 72.6 ng/L.

The authors concluded that the Minicare BNP assay under development is a fast, robust and sensitive test that can be used in a near-patient setting on capillary or EDTA venous whole blood sample. The Minicare BNP test has the potential for good clinical performance in the diagnosis of HF in various patient settings. The study was published in the May 2019 issue of the journal Practical Laboratory Medicine.

Related Links:
Medical University of Innsbruck

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.