Compact AI-Powered Microscope Enables Rapid Cost-Effective Cancer Scoring

By LabMedica International staff writers
Posted on 04 Sep 2025

Digital pathology is essential for modern cancer diagnostics, particularly for evaluating biomarkers like HER2, which guide breast cancer treatment decisions. More...

However, conventional whole-slide imaging scanners are prohibitively expensive, costing over USD 100,000, and their large size limits use in many labs and resource-limited settings. To address these challenges, researchers have now developed a compact scanning microscope that uses artificial intelligence (AI) to extract diagnostic value from blurred tissue images at a fraction of the cost.

BlurryScope, a portable, cost-effective scanning microscope, has been designed by researchers at UCLA (Los Angeles, CA, USA) for HER2 scoring in breast cancer tissue samples. Built for under USD 650 and weighing just 2.26 kg, the device measures 35 x 35 x 35 cm, making it highly accessible. Unlike conventional microscopes that capture sharp still images, BlurryScope continuously scans slides, producing motion-blurred images that are then analyzed by a deep neural network trained to classify HER2 expression.

In blinded experiments with 284 patient tissue cores, the system achieved nearly 80% accuracy across standard HER2 scoring categories and almost 90% accuracy when grouped into clinically actionable categories. Repeated scans of the same samples demonstrated reproducibility, with more than 86% of classifications matching across multiple runs. The results, published in npj Digital Medicine, validate both the robustness of the AI and the reliability of the device for clinical application.

BlurryScope automates the workflow from scanning to classification, enabling rapid triage, preliminary assessments, and use in clinics where high-end systems are impractical. Beyond HER2 scoring, the same AI-powered approach could extend to other tissue stains, biomarker analyses, and even different imaging modalities. By co-designing optical systems and AI algorithms, the technology demonstrates a pathway toward simplifying biomedical imaging hardware while broadening diagnostic access worldwide.

“With BlurryScope, we are redefining what affordable microscopy can look like,” said Dr. Aydogan Ozcan, Chancellor’s Professor of Electrical and Computer Engineering at UCLA. “By harnessing deep learning to interpret motion-blurred images, we can deliver clinically meaningful HER2 scoring at a fraction of the cost and size of conventional pathology scanners.”

Related Links:
UCLA


New
Gold Member
Automatic Hematology Analyzer
DH-800 Series
Collection and Transport System
PurSafe Plus®
New
Anterior Nasal Specimen Collection Swabs
53-1195-TFS, 53-0100-TFS, 53-0101-TFS, 53-4582-TFS
New
Automated Chemiluminescence Immunoassay Analyzer
MS-i3080
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: New research points to protecting blood during radiation therapy (Photo courtesy of 123RF)

Pioneering Model Measures Radiation Exposure in Blood for Precise Cancer Treatments

Scientists have long focused on protecting organs near tumors during radiotherapy, but blood — a vital, circulating tissue — has largely been excluded from dose calculations. Each blood cell passing through... Read more

Immunology

view channel
Image: The test could streamline clinical decision-making by identifying ideal candidates for immunotherapy upfront (Xiao, Y. et al. Cancer Biology & Medicine July 2025, 20250038)

Blood Test Predicts Immunotherapy Efficacy in Triple-Negative Breast Cancer

Triple-negative breast cancer (TNBC) is an aggressive subtype lacking targeted therapies, making immunotherapy a promising yet unpredictable option. Current biomarkers such as PD-L1 expression or tumor... Read more

Technology

view channel
Image: The sensor can help diagnose diabetes and prediabetes on-site in a few minutes using just a breath sample (Photo courtesy of Larry Cheng/Penn State)

Graphene-Based Sensor Uses Breath Sample to Identify Diabetes and Prediabetes in Minutes

About 37 million U.S. adults live with diabetes, and one in five is unaware of their condition. Diagnosing diabetes often requires blood draws or lab visits, which are costly and inconvenient.... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.