Liver Receptor Mediates Fat Metabolism

By Biotechdaily staff writers
Posted on 26 Apr 2005
Researchers have found that the body's liver X receptor (LXR), a protein known to regulate cholesterol metabolism, is able to selectively sense the cholesterol component of a lipid-rich diet and to activate proteins that use this cholesterol to maintain the balance between storage and oxidation of dietary fat.

Investigators at the University of Texas Southwestern Medical Center (Dallas, USA) genetically engineered a line of mice lacking the gene for LXR. More...
These animals were defective in hepatic lipid metabolism and were resistant to obesity when challenged with a diet containing both high fat and cholesterol. However, when given a high-fat diet containing no cholesterol, these mice were able to store fat. These findings were published in the April 2005 issue of Cell Metabolism.

Previous research had shown that LXRs activate the gene responsible for making SREBP-1c, a protein that is the primary component in the biochemical pathway that regulates fat metabolism. "LXR, this cholesterol sensor, is required for SREBP-1c to be expressed, to get SREBP-1c to initiate its role in regulating fat storage,” explained senior author Dr. David Mangelsdorf, professor of pharmacology and biochemistry at the University of Texas Southwestern Medical Center. "SREBP-1c had been considered the master regulator of fat synthesis, but our studies have shown that LXR is the master regulator of the master regulator. Our work suggests that fat storage is inextricably linked to the body's ability to metabolize cholesterol, and that the LXRs have evolved as the sensors that govern the unique cross between these two important metabolic pathways.”






Related Links:
U. of Texas Southwestern Med. Center

Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Fully-auto Specific Protein (Nephelometry) Analyzer
PA240
Automated Urinalysis Solution
UN-9000
New
Gastrointestinal Panel
Xpert® GI Panel
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Microbiology

view channel
Image: Schematic overview of the CRISPR-Assisted Nanodroplet-pairing Platform for Differential Identification of NTM (CANDI). The platform combines broad-range amplification using conserved regions of the 16S and 23S rRNA genes with species-specific CRISPR recognition. Fluorescence-coded CRISPR droplets are paired with sample droplets containing amplified products, enabling multiplexed target recognition and signal decoding (Image Credit: Yiwen Yang, Jingsong Xu, Dakang Xu)

Nanodroplet CRISPR Technology Supports Rapid, Multiplexed Mycobacterial Identification

Mycobacterial infections are difficult to diagnose because closely related species can have different clinical and therapeutic implications. Nontuberculous mycobacteria (NTM) are increasingly recognized... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image: TruVerus is designed to deliver a broad menu of routine blood tests from a small blood sample on a single, automated benchtop platform (Photo courtesy of Truvian Health)

Collaboration Advances Automated Benchtop Platform for Routine Blood Testing

Routine blood testing is central to clinical decision-making, but access can vary across laboratory and healthcare settings. Broader use of automated benchtop platforms may help integrate testing more... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.