We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
INTEGRA BIOSCIENCES AG

Roche Diagnostics

Develops, manufactures, and markets a wide range of in vitro diagnostic systems, instruments, reagents, and tests read more Featured Products: More products

Download Mobile App




Novel Assay Measures Interleukin-6 in Whole Blood Samples

By LabMedica International staff writers
Posted on 05 Oct 2021
Print article
Image: The Pylon 3D Fully Automated Immunoassay System (Photo courtesy of ET Healthcare)
Image: The Pylon 3D Fully Automated Immunoassay System (Photo courtesy of ET Healthcare)
Interleukin 6 (IL-6) is a pleiotropic cytokine produced by various stromal cells and immune system cells, involved in inflammation and infection responses, regeneration process, metabolism regulation, bone homeostasis, and neural functions.

Interleukin 6 assays are useful in early detection of infections and risk stratification of critically ill patients, so an assay with a short turnaround-time and near-patient use is preferred. It is indicated in many diseases such as infection, injury, trauma, stress, neoplasia, post-surgery complications, and chronic inflammatory diseases.

Clinical Laboratorians at the Children’s Hospital of Fudan University (Shanghai, China) included in a study pediatric patients, admitted to the Emergency Department (ED) between April and September 2020 with suspected infection. Blood samples and respiratory tract samples were collected for routine clinical laboratory tests, that is, hematology tests, CRP, PCT, viral antigen, or antibody tests and microbiology culture tests.

The study evaluated the performance of the Pylon IL-6 assay (ET Healthcare, Shanghai, China) based on a cyclic enhanced fluorescent immunoassay performed on a fully automated, benchtop Pylon 3D immuno-analyzer. A total of 100 remnant serum samples from outpatients and ED patients were measured by the Pylon assay and the Elecsys IL-6 assay on a Cobas e 602 (Roche Diagnostics, Rotkreuz, Switzerland). The team carried out imprecision, linearity and comparison studies using serum and plasma samples according to CLSI EP guidelines. The stability of whole blood (WB) samples during storage was assessed.

The investigators reported that the results of serum samples measured by Pylon assays correlated to those measured by Roche assays, as well as to those of matched whole blood samples measured by Pylon assays. IL-6 in whole blood was found stable for ~8 hours at room temperature. Pylon IL-6 results of whole blood samples from 179 pediatric patients with suspected infection showed an AUC of 0.842 in diagnosis of bacterial infection. The within-run CVs and total CVs of Pylon IL-6 assay were determined as 1.8% and 3.0% at 159.3 pg/mL and 3.5% and 4.7% at 8009.9 pg/mL, respectively. The method showed linearity between 1.5 and 42,854 pg/mL. The turnaround time of Pylon IL-6 assay was only an hour when using whole blood samples.

The authors concluded that the new Pylon IL-6 assay demonstrated comparable performance to those assays performed on clinical laboratory instruments. Further, the feature of WB sampling offers advantages in ED or other near-patient settings where turnaround time (TAT) is critical. The study was published on September 20, 2021 in the Journal of Clinical Laboratory Analysis.

Related Links:
Children’s Hospital of Fudan University
ET Healthcare
Roche Diagnostics


Gold Member
Pharmacogenetics Panel
VeriDose Core Panel v2.0
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Creatine Kinase-MB Assay
CK-MB Test
New
Hemoglobin/Haptoglobin Assay
IDK Hemoglobin/Haptoglobin Complex ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.