New Automated Periostin Immunoassay Developed

By LabMedica International staff writers
Posted on 11 Jan 2017
Periostin is being investigated as a potential biomarker for T-helper-2 (Th2)-driven asthma or eosinophilic inflammation and may help to identify patients more likely to benefit from interleukin-13-targeted treatments.

The use of serum interleukin-13 (IL-13) itself as a biomarker is challenging because it is expressed locally in inflamed tissue, resulting in very low concentrations in serum and concentrations of serum IL-13 appear to be similar between healthy controls and subjects with asthma.

Scientists at Abbott Laboratories (Abbott Park, IL, USA) and their colleagues assessed the company’s ARCHITECT Periostin Immunoassay performance in terms of precision, sensitivity, linearity, interference from classical immunoassay interferents and representatives of common asthma medications, specimen handling, and isoform reactivity. The assay has been developed for use with the ARCHITECT Immunoassay i System.

Samples from subjects with idiopathic pulmonary fibrosis, subjects with asthma used in periostin concentration assessments, and normal samples from healthy volunteers were obtained. The test is a monoclonal antibody (mAb) sandwich two-step immunoassay for the quantitative determination of periostin in human serum using chemiluminescent magnetic immunoassay technology. Periostin, the analyte, is captured by microparticles coated with an anti-periostin mAb and subsequently detected with a second anti-periostin mAb conjugated with Acridinium.

The team reported that the percentage of coefficient of variation (CVs) for five-day total precision, assessed using two instruments was less than 6% across two controls and one serum-based panel. Limit of quantitation was 4 ng/mL, using dilution adjusted concentration, suiting the needs for the application. Dilution analysis yielded linear results and no endogenous sample or drug interferences were observed. All known periostin isoforms expressed in the mature human lung were detected by the assay.

The authors concluded that their analysis of periostin concentration in serum samples appeared to show slightly elevated mean periostin concentrations in samples from subjects with uncontrolled asthma compared with apparently healthy volunteers. This is consistent with reports of elevated serum periostin concentration in subjects with asthma, particularly those with Th2-driven asthma or eosinophilic inflammation. The study was published in the January 2017 issue of the journal Clinica Chimica Acta.

Related Links:
Abbott Laboratories


Gold Member
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
New
IGFBP-1 Rapid Test
AMNISTRIP
New
Adrenocorticotropic Hormone ELISA
ACTH ELISA
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: The new saliva-based test for heart failure measures two biomarkers in about 15 minutes (Photo courtesy of Trey Pittman)

POC Saliva Testing Device Predicts Heart Failure in 15 Minutes

Heart failure is a serious condition where the heart muscle is unable to pump sufficient oxygen-rich blood throughout the body. It ranks as a major cause of death globally and is particularly fatal for... Read more

Molecular Diagnostics

view channel
Image: New Alzheimer’s studies have revealed disease biology, risk for progression, and potential for a novel blood test (Photo courtesy of Adobe Stock)

Novel Blood Test Could Reveal Alzheimer’s Disease Biology and Risk for Progression

The inability to diagnose Alzheimer’s disease, the most prevalent form of dementia in the elderly, at an early stage of molecular pathology is considered a key reason why treatments fail in clinical trials.... Read more

Hematology

view channel
Image: The discovery of a new blood group has solved a 50- year-old mystery (Photo courtesy of 123RF)

Newly Discovered Blood Group System to Help Identify and Treat Rare Patients

The AnWj blood group antigen, a surface marker discovered in 1972, has remained a mystery regarding its genetic origin—until now. The most common cause of being AnWj-negative is linked to hematological... Read more

Microbiology

view channel
Image: The Accelerate WAVE system delivers rapid AST directly from positive blood culture bottles (Photo courtesy of Accelerate Diagnostics)

Rapid Diagnostic System to Deliver Same-Shift Antibiotic Susceptibility Test Results

The World Health Organization estimates that sepsis impacts around 49 million people worldwide each year, resulting in roughly 11 million deaths, with about 1.32 million of these deaths directly linked... Read more

Pathology

view channel
Image: Virtual birefringence imaging and histological staining of amyloid deposits in label-free tissue (Photo courtesy of Ozcan Research Group)

AI-Based Tissue Staining Detects Amyloid Deposits Without Chemical Stains or Polarization Microscopy

Systemic amyloidosis, a disorder characterized by the buildup of misfolded proteins in organs and tissues, presents significant diagnostic difficulties. The condition affects millions of people each year,... Read more

Industry

view channel
Image: The Scopio X100 and X100HT full-field digital cell morphology solution (Photo courtesy of Beckman Coulter)

Beckman Coulter and Scopio Labs Add World's First Digital Bone Marrow Imaging and Analysis to Long-Term Partnership

Since 2022, Beckman Coulter (Brea, CA, USA) and Scopio Labs (Tel Aviv, Israel) have been working together to accelerate adoption of the next generation of digital cell morphology. Scopio's X100 and X100HT... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.