Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Vascular Disease Plasma Marker Confirmed in Diabetes Patients

By LabMedica International staff writers
Posted on 02 Feb 2016
Pre-kallikrein (PK) has previously been suggested as a marker for diabetic vascular disease of the kidneys, but a new study supports the idea that increased plasma PK levels are an independent risk factor for whole-body diabetic vascular disease, similar to the risks of high triglycerides or high blood pressure in heart disease.

The types of blood vessel malfunction seen in patients with diabetes causes the cells of the intima-media to spread to the surface, allowing PK to contact them directly and this contact closes the circuit of an alternative pathway of chronic inflammation. More...
Scientists who study the kallikrein-kinin system suspect that this chronic inflammation is responsible for the blood vessel thickening observed in diabetic kidney disease, retinopathy, and atherosclerosis.

Scientists at the Medical University of South Carolina (Charleston, SC, USA) and their colleagues enrolled participants in Epidemiology of Diabetes Interventions and Complications (EDIC), a multicenter longitudinal observational study of the development of macrovascular complications and further progression of microvascular complications. The study was conducted on a subset of 636 subjects from the Diabetes Control and Complications Trial DCCT/EDIC cohort.

Plasma PK was activated with ∼0.4 nmol/L Hageman factor fragment (betaFXIIa), and the formed plasma kallikrein was detected by hydrolysis of the chromogenic substrate H-D-Pro-Phe-Arg-paranitroanilide (DiaPharma; Franklin, OH, USA) according to the published procedure, and was expressed as units per milliliter (U/mL). Factor XII:coagulant and high molecular weight kininogen (HK):coagulant, plasma concentrations of fibrinogen and plasminogen activator inhibitor (PAI-1) activity levels were also determined. Carotid intima-media thickness was measured by B-mode ultrasonography.

The circulating levels of plasma PK were measured in 636 type 1 diabetic subjects from plasma collected in years 1997–1999. The PK levels were symmetrically distributed and ranged from 0.2-3.0 U/mL, with a mean value of 1.29 U/mL. A positive and significant association was found between PK levels and body mass index (BMI), and with HbA1c, a marker of metabolic control. They also found that patients with higher levels of PK in their blood have thicker layers of intima-media in the vasculature of their carotids.

Ayad A. Jaffa, PhD, the senior author of the study said, “These preclinical studies not only will give us insights into the involvement of plasma PK in vascular disease, but will also contribute to development of novel treatment strategies for diabetic vascular disease.” The study was published ahead of print on November 24, 2015, in the journal Diabetes.

Related Links:

Medical University of South Carolina 
DiaPharma 



Gold Member
Respiratory Syncytial Virus Test
OSOM® RSV Test
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Capillary Blood Collection Tube
IMPROMINI M3
Sperm Quality Analyis Kit
QwikCheck Beads Precision and Linearity Kit
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.