We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Sekisui Diagnostics

CEPHEID

Develops, manufactures, and markets molecular systems and tests for institutions to perform sophisticated genetic tes... read more Featured Products: More products

Download Mobile App




POC Test Advances Hepatitis C Diagnosis

By LabMedica International staff writers
Posted on 10 May 2017
A new test that enables diagnosis of hepatitis C infection in a single visit could improve access to early diagnosis, monitoring, and treatment service for some of the most vulnerable people in Australia and the world.

Point-of-care hepatitis C virus (HCV) RNA testing offers an advantage over antibody testing, which only indicates previous exposure, enabling diagnosis of active infection in a single visit. More...
The performance of a HCV Viral Load assay with venipuncture and finger-stick capillary whole-blood samples has been evaluated.

Scientists at the Kirby Institute collected plasma and finger-stick capillary whole-blood samples from participants in an observational cohort enrolled at five sites in Australia, three drug and alcohol clinics, one homelessness service, and one needle and syringe program. Of 210 participants enrolled between February 8, 2016, and July 27, 2016, 150 participants had viral load testing results for the three assays tested.

The scientists compared the sensitivity and specificity of the Xpert HCV Viral Load test for HCV RNA detection by venipuncture and finger-stick collection with their gold standard, the Abbott RealTime HCV Viral Load assay. The Xpert HCV Viral Load test is a quantitative test for rapid measurement of Hepatitis C virus Viral Load and confirmation of HCV infection delivers on-demand results in less than two hours.

HCV RNA was detected in 45 (30%) of 150 participants based on the Abbott RealTime assay. Sensitivity of the Xpert HCV Viral Load assay for HCV RNA detection in plasma collected by venipuncture was 100% and specificity was 99.1%. Sensitivity of the Xpert HCV Viral Load assay for HCV RNA detection in samples collected by finger-stick was 95.5% and specificity was 98.1%. No adverse events caused by the index test or the reference standard was observed. The authors concluded that the Xpert HCV Viral Load test can detect active infection from a finger-stick sample, which represents an advance over antibody-based tests that only indicate past or previous exposure.

Jason Grebely, PhD, an Associate Professor and lead author of the study, said, “Requiring people to come back for a second appointment to receive their results can present significant barriers, especially for people living in remote areas and for vulnerable and marginalized populations like homeless people and people who inject drugs, who are the people we need to reach the most in order to eliminate hepatitis C.” The study was published on April 21, 2017, in the journal The Lancet Gastroenterology & Hepatology.


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Platelet Function Analyzer
PL-12
New
Alzheimer's Disease Biomarker Assay
Elecsys Phospho-Tau (217P) Plasma
Gold Member
Blood-Based Protein Biomarker Solution for Alzheimer's Disease
BG-DTi2000.
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image Credit: 123RF

Screening After Pneumococcal Disease May Reveal Undiagnosed Blood Cancer or Immune Disorders

Severe pneumococcal disease requiring hospitalization often presents as pneumonia, particularly in older adults and people with cancer or compromised immune function. Because M protein testing and antibody... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image

Collaboration Combines AI Cognitive Assessment and RNA Blood Testing for Earlier Alzheimer’s Detection

Alzheimer’s disease is often identified only after substantial neurodegeneration, partly because current diagnostic pathways are fragmented and difficult to scale. As treatment shifts toward earlier intervention,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.