Three Automated Urine Analyzers Compared with Manual Microscopic Urinalysis

By LabMedica International staff writers
Posted on 03 Mar 2021
Print article
Image: The iRICELL series combines urine chemistry and microscopy in a fully automated, walk-away workcell that is easy to use and maintain and optimizes and advances urinalysis and body fluid testing (Photo courtesy of Beckman Coulter).
Image: The iRICELL series combines urine chemistry and microscopy in a fully automated, walk-away workcell that is easy to use and maintain and optimizes and advances urinalysis and body fluid testing (Photo courtesy of Beckman Coulter).
Urinalysis is an essential screening test in clinical laboratories in order to diagnose and plan treatment for urinary tract infections, kidney disease and diabetes. Urinalysis includes visual examination, evaluation of chemical parameters and microscopic examination.

Microscopic examination is fundamental to urine analysis. This is a simple way to collect informative data, but it is also labor-intensive, time-consuming, and requires experienced staff for accurate results and interpretation. Several automated urine analyzers have been introduced for urine analysis in medical laboratories.

Clinical Medical Laboratorians at the Prince of Songkla University (Songkhla, Thailand) collected fresh 100 urine samples in preservative-free containers and transferred to four different test tubes for three automated urine analyzers without centrifuging and manual microscopy by three experienced medical technologists, independently using the same microscope slide.

The scientists assessed and compared the performance of the most common three automated urine analyzers: Cobas 6500 (Roche Diagnostics, Indianapolis, IN, USA); UN3000-111b (Sysmex Corporation, Kobe, Japan); and iRICELL 3000 (Beckman Coulter, Brea, CA, USA). The Cobas 6500 is a combination of two analyzers including the Cobas u601 which analyzes physical and chemical components, and the Cobas u701 which performs microscopic examinations. The UN3000-111b has two component analyzers in a single platform including a chemical component (UC-3500 analyzer) for analyzing the physical and chemical parts of urine and a fluorescence flow cytometry component (UF-5000 analyzer) for microscopic examination of sediments. The iRICELL 3000 is a combination of two component analyzers including a chemical component (iChemVELOCITY) and a microscopic examination component (iQ200).

The medical laboratorians reported that there was good correlation of urine physical and chemical analyses between the three analyzers with an overall concordance level of more than 80%. For sediment analysis, the degree of concordance between manual analysis and the three instruments was very good to good for white blood cells, red blood cells and epithelial cells, and moderate for bacteria. There were fair to good agreements between manual microscopy and the three instruments, Cobas 6500, UN3000-111b and iRICELL 3000, for casts (Cohen’s kappa 0.42, 0.38 and 0.62, respectively).

The authors concluded that the three automated urine analyzers showed similar performances and good correlation with manual microscopy. The results of this study indicate that automated urine analyzers could be used for initial urine testing to reduce high workloads and to save time, but manual microscopic analysis by experienced staff is still necessary to classify urine sediments for confirmation, especially in pathologic specimens. The study was published in the March, 2021 issue of the journal Practical Laboratory Medicine.

Related Links:
Prince of Songkla University
Roche Diagnostics
Sysmex Corporation
Beckman Coulter


Gold Supplier
Fluorimetric Immunoassay Analyzer
Confiscope F20
New
Vented Safety Enclosures
VSE Balance Enclosures
New
Silver Supplier
Immunoassay Reader
VEGA-200 Reader
New
Mechanical Pipette
Accumax Smart

Print article

Channels

Molecular Diagnostics

view channel
Image: Model of the PD-1 (Programmed cell death protein 1) protein. Only a subset of recurrent glioblastomas respond to anti-PD-1 immunotherapy (Photo courtesy of Wikimedia Commons)

Biomarker Predicts Potential Benefit of Checkpoint Inhibitor Therapy for Brain Cancer Patients

A phosphorylated form of ERK (extracellular signal-regulated kinase) protein has been identified as a biomarker that may be used to predict which brain cancer patients might benefit from checkpoint inhibitor... Read more

Hematology

view channel
Image: The UniCel DxH 800 Coulter Cellular Analysis System (Photo courtesy of Beckman Coulter)

Monocyte Distribution Width Predicts Sepsis in Critically Ill Patients

Sepsis has been reported as a major cause of increased morbidity, length of stay and mortality among patients hospitalized in Intensive Care Units (ICUs) for any cause. The survival of patients developing... Read more

Immunology

view channel
Image: Procartaplex Immunoassays Kits are based on the principles of a sandwich ELISA, using two highly specific antibodies binding to different epitopes of one protein to quantitate all protein targets simultaneously (Photo courtesy of Thermo Fisher Scientific)

Assay Developed for Patient-Specific Monitoring and Treatment for Ovarian Cancer

Tumors can influence peripheral immune macroenvironment, thereby creating opportunities for non-invasive serum/plasma immunobiomarkers for immunostratification and immunotherapy designing.... Read more

Microbiology

view channel
Image: Clinical metagenomics (CMg) using nanopore sequencing (Photo courtesy of Oxford Nanopore Technologies)

Same Day Test Identifies Secondary Infections in COVID-19 Patients

The intensive care unit (ICU) is a dynamic environment with frequent staff-patient contact for invasive monitoring, interventions and personal care that together introduce the risk of secondary or nosocomial... Read more

Pathology

view channel
Image: The Ventana BenchMark Ultra autostainer is for cancer diagnostics with automation and the test menu include IHC, ISH, and FITC tests (Photo courtesy of Ventana Medical System)

Specific Biomarker Investigated for Triple-Negative Breast Cancer Diagnosis

Triple-negative breast cancer (TNBC) is defined by the lack of estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2) expression and comprises a heterogeneous... Read more

Technology

view channel
Image: PKeye Workflow Monitor System (Photo courtesy of PerkinElmer, Inc.)

PerkinElmer’s New Cloud-Based Platform Enables Laboratory Personnel to Remotely Manage Its Instruments in Real-Time

PerkinElmer, Inc. (Waltham, MA; USA) has launched its PKeye Workflow Monitor, a cloud-based platform enabling laboratory personnel to remotely manage and monitor their PerkinElmer instruments and workflows... Read more

Industry

view channel
Illustration

Global HBA1c Laboratory Tests Market Driven by Rise in Diabetic Population

The global HBA1c laboratory tests market is projected to expand at a significant pace over the coming years, driven by an increase in the prevalence of diabetes, rise in prescription rate of HBA1c tests... Read more
Copyright © 2000-2021 Globetech Media. All rights reserved.