We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Siemens Healthineers - Laboratory Diagnostics

Provides advanced laboratory diagnostics solutions for the medical industry read more Featured Products: More products

Download Mobile App




Maternal Free Thyroxine Associated with Gestational Diabetes

By LabMedica International staff writers
Posted on 06 May 2021
Print article
Image: Immulite 2000 XPi immunoanalyzer system (Photo courtesy of Siemens Healthcare Diagnostics)
Image: Immulite 2000 XPi immunoanalyzer system (Photo courtesy of Siemens Healthcare Diagnostics)
Hyperglycemia resulting from glucose intolerance during pregnancy, known as gestational diabetes mellitus (GDM), is a common complication during pregnancy and has a major impact on public health worldwide.

Human chorionic gonadotropin (hCG) is routinely used for first trimester Down's syndrome screening programs worldwide. hCG could be a determinant of GDM risk as it has been shown to stimulate placental glycogenolysis through activation of adenylate cyclase and its immunomodulatory effects could ameliorate pancreatic autoimmunity. Decreased thyroid function has been found to be associated with a higher risk of GDM.

Medical Scientists at the Erasmus Medical Center (Rotterdam, The Netherlands) and their Chinese colleagues analyzed data from 18,683 pregnant women (mean age, 29 years; mean gestational age, 12.1 weeks; 84.5% primiparous) presenting at a tertiary hospital in Shanghai from 2015 to 2016. Fasting blood samples were obtained in the first trimester (between 9 and 13 weeks).

Quantitative analyses of thyrotropin (TSH) and serum free thyroxine (fT4) and thyroperoxidase antibody (TPOAb) concentrations were measured with kits (ARCHITECT i2000; Abbott, Chicago, IL). hCG serum concentrations were determined by a solid-phase, two-site, chemiluminescent immunometric assay on the Immulite 2000 XPi system (Siemens Healthcare Diagnostics, Deerfield, IL, USA). Fasting plasma glucose (FPG) concentrations were tested at the first antenatal screening visit using a GOD-PAP kit (Human, Wiesbaden, Germany). Hemoglobin A1c (HbA1c) concentrations were measured using Roche Diagnostics HbA1c kits with a Cobas Integra 800 autoanalyzer (Roche Diagnostics, Mannheim, Germany).

The team reported that higher hCG concentrations were associated with a lower plasma glucose level during the oral glucose tolerance test (OGTT), but not with fasting plasma glucose or hemoglobin A1c concentrations tested during early pregnancy. In the sensitivity analysis restricted to TPOAb-positive women, hCG was not associated with GDM. Within the cohort, median thyroid-stimulating hormone was 1.15 mU/L, median free T4 was 15 pmol/L, and 1,833 women (9.8%) were TPOAb positive. hCG in early pregnancy was negatively associated with GDM risk. Mediation analysis identified that an estimated 21.4% of the association of hCG-associated GDM risk was mediated through changes in free thyroxine (fT4) concentrations.

Tim I. M. Korevaar, MD, PhD, a translational epidemiologist and a senior author of the study, said, “These data provide new insights into how thyroid physiology could affect the risk for gestational diabetes, after replication of which, these data can be used to identify high-risk populations. It will be relevant to study the mechanism via which hCG may have a beneficial effect on glucose homeostasis, and further studies on the relevance of adequate hCG stimulation of thyroid function during pregnancy are needed to improve the clinical risk assessment related to thyroid function test abnormalities in pregnancy.”

The authors concluded that higher hCG levels in early pregnancy are associated with a lower risk of GDM, which could be mediated by maternal fT4 concentrations. The study provided new insights into the potential mechanism involved in the development of glucose intolerance. The study was published on April 21, 2021 in the journal Thyroid.

Related Links:
Erasmus Medical Center
Abbott
Siemens Healthcare Diagnostics
Human
Roche Diagnostics


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
HLX
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Molecular Diagnostics

view channel
Image: The study showed the blood-based cancer screening test detects 83% of people with colorectal cancer with specificity of 90% (Photo courtesy of Guardant Health)

Blood Test Shows 83% Accuracy for Detecting Colorectal Cancer

Colorectal cancer is the second biggest cause of cancer deaths among adults in the U.S., with forecasts suggesting 53,010 people might die from it in 2024. While fewer older adults are dying from this... Read more

Hematology

view channel
Image: The Gazelle Hb Variant Test (Photo courtesy of Hemex Health)

First Affordable and Rapid Test for Beta Thalassemia Demonstrates 99% Diagnostic Accuracy

Hemoglobin disorders rank as some of the most prevalent monogenic diseases globally. Among various hemoglobin disorders, beta thalassemia, a hereditary blood disorder, affects about 1.5% of the world's... Read more

Microbiology

view channel
Image: The new platform is designed to perform blood-based diagnoses of nontuberculosis mycobacteria (Photo courtesy of 123RF)

New Blood Test Cuts Diagnosis Time for Nontuberculous Mycobacteria Infections from Months to Hours

Breathing in nontuberculous mycobacteria (NTM) is a common experience for many people. These bacteria are present in water systems, soil, and dust all over the world and usually don't cause any problems.... Read more

Industry

view channel
Image: These new assays are being developed for use on the recently introduced DxI 9000 Immunoassay Analyzer (Photo courtesy of Beckman Coulter)

Beckman Coulter and Fujirebio Expand Partnership on Neurodegenerative Disease Diagnostics

Beckman Coulter Diagnostics (Brea, CA, USA) and Fujirebio Diagnostics (Tokyo, Japan) have expanded their partnership focused on the development, manufacturing and clinical adoption of neurodegenerative... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.