Saliva Specimens Diagnose Respiratory Virus by POC Assay

By LabMedica International staff writers
Posted on 05 Jul 2018
Print article
Image: The Xpert Xpress Flu/RSV Assay Cassette (Photo courtesy of Cepheid).
Image: The Xpert Xpress Flu/RSV Assay Cassette (Photo courtesy of Cepheid).
The use of saliva as a specimen for the detection of respiratory viruses has been proposed as an alternative to nasopharyngeal aspirate or nasopharyngeal swab: saliva may have the advantage to cause less discomfort in patients and less risk for healthcare workers.

Automated point-of-care molecular assays have greatly shortened the turnaround time of respiratory virus testing. One of the major bottlenecks now lies at the step of the specimen collection especially in a busy clinical setting. Saliva is a convenient specimen type, which can be provided easily from adult patients.

Scientists from the University of Hong Kong (Pokfulam, Hong Kong) recruited between July and October 2017, 214 patients and carried out a prospective diagnostic validity study comparing the detection rate of respiratory viruses between saliva and nasopharyngeal aspirate (NPA) among adult hospitalized patients using Xpert Xpress Flu/RSV. The cost and time associated with the collection of saliva and nasopharyngeal specimens were also estimated.

The team found that the overall agreement between saliva and NPA were 93.3% (196/210). There was no significant difference in the detection rate of respiratory viruses between saliva and NPA; (69/210 (32.9%) versus 75/210 (35.7%). The overall sensitivity and specificity were 90.8% (81.9-96.2%) and 100% (97.3-100%), respectively, for saliva, and were 96.1% (88.9-99.2%) and 98.5% (94.7-99.8%), respectively, for NPA. The time and cost associated with the collection of saliva were 2.3-fold and 2.6-fold lower, respectively, than those of NPA.

The authors concluded that saliva specimen had high sensitivity and specificity in the detection of respiratory viruses by an automated multiplex Clinical Laboratory Improvement Amendments (CLIA)-waived point-of-care molecular assay when compared with that of NPA. The use of saliva also reduces the time and cost associated with specimen collection. The study was published on June 12, 2018, in the journal Clinical Microbiology and Infection.

Related Links:
University of Hong Kong

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.