A new test can quickly and easily assess how well a person’s neutralizing antibodies fight infection from multiple variants of COVID-19 such as Delta and the newly discovered Omicron variant. More...

The test devised by biomedical engineers at Duke University (Durham, NC, USA) could potentially tell doctors how protected a patient is from new variants and those currently circulating in a community or, conversely, which monoclonal antibodies to treat a COVID-19 patient. The researchers have dubbed their test the COVID-19 Variant Spike-ACE2-Competitive Antibody Neutralization assay, or CoVariant-SCAN for short. The test’s technology hinges on a polymer brush coating that acts as a sort of non-stick coating to stop anything but the desired biomarkers from attaching to the test slide when wet. The high effectiveness of this non-stick shield makes the test incredibly sensitive to even low levels of its targets. The approach allows researchers to print different molecular traps on different areas of the slide to catch multiple biomarkers at once.

In this application, the researchers print fluorescent human ACE2 proteins—the cellular targets of the virus’s infamous spike protein—on a slide. They also print spike proteins specific to each variant of COVID-19 at different specific locations. When the test is run, the ACE2 proteins detach from the slide and are caught by the spike proteins still attached to the slide, causing the slide to glow. But in the presence of neutralizing antibodies, the spike proteins are no longer able to grab on to the ACE2 proteins, making the slide glow less, indicating the effectiveness of the antibodies. By printing different variants of the COVID-19 spike protein on different portions of the slide, researchers can see how effective the antibodies are at preventing each variant from latching onto their human cellular target simultaneously.

While they produce similar results, the critical difference between the CoVariant-SCAN and current methods is the speed and ease with which it can produce results. Typical current approaches require isolating live virus and culturing cells, which can take 24 hours or more and requires a wide variety of safety precautions and specially trained technicians. The CoVariant-SCAN, in contrast, does not require live virus, is easy to use in most settings and takes less than an hour—potentially just 15 minutes—to produce accurate results. Moving forward, the researchers are working to streamline the technique into a microfluidic chip that could be mass produced and report results with only a few drops of blood, plasma or other liquid sample containing antibodies. This approach has already been proven to work on a similar test that can distinguish COVID-19 from other coronaviruses.

“We would love to have real-time visibility of the emerging variants and understand who still has functional immunity,” said Cameron Wolfe, associate professor of medicine at the Duke University School of Medicine. “Additionally, this hints that there might be a technique whereby you could quickly assess which synthetic monoclonal antibody might be best to administer to a patient with a particular emergent variant. Currently we really have no real-time way of knowing that, so we rely on epidemiological data that can track weeks behind.”

“The reverse is also true. To be able to pre-screen an individual's antibodies and predict whether they were sufficiently protected against a particular variant they are perhaps about to run into while travelling, or that is emerging in their area. We have no way of doing that at the present time. But a test like the CoVariant-SCAN could make all of these scenarios possible,” added Wolfe.

Related Links:
Duke University 


Gold Member
Multiplex Genetic Analyzer
MassARRAY Dx Analyzer (Europe only)
3-Part Differential Hematology Analyzer
Swelab Alfa Plus Sampler
New
Staining Management Software
DakoLink
New
Automatic Hematology Analyzer
LABAS F9000
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








DIASOURCE (A Biovendor Company)

Channels

Hematology

view channel
Image: CitoCBC is the world first cartridge-based CBC to be granted CLIA Waived status by FDA (Photo courtesy of CytoChip)

Disposable Cartridge-Based Test Delivers Rapid and Accurate CBC Results

Complete Blood Count (CBC) is one of the most commonly ordered lab tests, crucial for diagnosing diseases, monitoring therapies, and conducting routine health screenings. However, more than 90% of physician... Read more

Immunology

view channel
Image: A simple blood test could replace surgical biopsies for early detecion of heart transplant rejection (Photo courtesy of Shutterstock)

Blood Test Detects Organ Rejection in Heart Transplant Patients

Following a heart transplant, patients are required to undergo surgical biopsies so that physicians can assess the possibility of organ rejection. Rejection happens when the recipient’s immune system identifies... Read more

Pathology

view channel
These images illustrate how precision oncology Organ Chips recapitulate individual patients’ responses to chemotherapy (Photo courtesy of Wyss Institute at Harvard University)

Cancer Chip Accurately Predicts Patient-Specific Chemotherapy Response

Esophageal adenocarcinoma (EAC), one of the two primary types of esophageal cancer, ranks as the sixth leading cause of cancer-related deaths worldwide and currently lacks effective targeted therapies.... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.