We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
INTEGRA BIOSCIENCES AG

Download Mobile App




Events

09 Apr 2024 - 12 Apr 2024
15 Apr 2024 - 17 Apr 2024
23 Apr 2024 - 26 Apr 2024

Samples Quality Improved Using Low-Vacuum Tubes

By LabMedica International staff writers
Posted on 16 Jul 2019
Print article
Image: The BD Barricor tube is a single-use, plastic evacuated tube with a mechanical separator used to collect, separate, transport and process venous blood specimens (Photo courtesy of Becton, Dickinson and Company).
Image: The BD Barricor tube is a single-use, plastic evacuated tube with a mechanical separator used to collect, separate, transport and process venous blood specimens (Photo courtesy of Becton, Dickinson and Company).
Centrifugation is a time consuming step, which contributes to increase the turnaround time (TAT) in laboratories, likewise hemolyzed samples that needs a re-sampling could delay management of patients.

So, the absence of hemolysis is one of the most important quality indicators for biochemistry as many analytes are influenced at the up or at the down with sample hemolysis. The hemolysis index is a measurement of the red color of serum. This color is normally due almost exclusively to the presence of hemoglobin, which comes from ruptured red blood cell membranes.

Medical biochemists and their colleagues at the Lapeyronie University Hospital (Montpellier, France) evaluated the impact of replacing BD vacutainer heparin lithium tube by low-vacuum BD Vacutainer Barricor tube in an emergency department (ED) on hemolysis rate and TAT. In the first phase blood tests for biochemistry were all performed using 4 mL plastic BD Vacutainer lithium heparin tubes and tubes were then centrifuged during 15 minutes  at 2,000g in an emergency dedicated Multifuge X3 FR Centrifuge.

After this first period, all 4 mL BD Vacutainer lithium heparin tubes were removed from the ED and replaced by 3.5 mL BD Vacutainer Barricor lithium heparin tubes during the one day of transition. Hemolysis Index (HI) was measured in the conventional unit (free hemoglobin mg/dL) on all tubes using the Cobas 8000 Roche test SSI-2 on a c701 module. Eight chemistry analytes were measured on the four different Cobas 8000 modules.

The scientists reported that a significantly reduced time duration between reception of sample and available results in informatics laboratory system was observed with the reduction time of centrifugation allowed by use of Barricor tube compared to regular heparin lithium tubes. A statistical significant decrease in hemolysis rate also occurred in the second period as samples with HI  less than 10 reached from 52.5% in the first period to 68.5% in the second.

The authors concluded that their study highlighted two advantages when using low-vacuum Barricor tubes which was a reduction of centrifugation time allowing improvement of laboratory TAT and a reduction of hemolyzed samples that improve sample and result quality. The study was published on June 12, 2019, in the journal Practical Laboratory Medicine.

Related Links:
Lapeyronie University Hospital

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Specimen Collection & Transport
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Molecular Diagnostics

view channel
Image: The cobas Malaria test is the first FDA-approved molecular test to screen U.S. blood donors for malaria (Photo courtesy of Roche)

First FDA-Approved Molecular Test to Screen Blood Donors for Malaria Could Improve Patient Safety

Malaria, a serious illness that often leads to death, is spread by a specific mosquito species that infect humans with a parasite. Other transmission modes include blood transfusions, organ transplants,... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The medical office procedure detects the key biomarker in Parkinson’s and related neurodegenerative diseases (Photo courtesy of BIDMC)

Simple Skin Biopsy Test Detects Parkinson’s and Related Neurodegenerative Diseases

Parkinson's disease and a group of related neurodegenerative disorders known as synucleinopathies impact millions globally. These conditions, including Parkinson’s disease (PD), dementia with Lewy bodies... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.