Collection Tubes Influence Targeted Metabolomics Studies

By LabMedica International staff writers
Posted on 08 Oct 2018
Print article
Image: The QTRAP 6500 Q-Trap mass spectrometer (MS) (Photo courtesy of Sciex).
Image: The QTRAP 6500 Q-Trap mass spectrometer (MS) (Photo courtesy of Sciex).
Plasma and serum are the most widely used matrices in clinical studies. However, some variability in absolute concentrations of metabolites are likely to be observed in these collection tubes matrices.

Selecting the correct matrix for biochemical analysis is of paramount importance in order to avoid improper diagnosis. Blood collection tubes are often an under-recognized variable in the pre-analytical phase of clinical studies, and it is thus important to evaluate the influences of these matrices during metabolomics analysis.

An international team of scientists working with the Institute for Biomedicine (Eurac Research, Bolzano, Italy) enrolled a total of 40 healthy independent individuals who were selected with age lower than 35 years and assigned to the “young” group. The other 40 healthy independent subjects were selected with age higher than 60 years and assigned to the “elderly” group. Blood was collected at the recruitment center after overnight fasting, and taken in the early morning within a short time interval.

Serum, EDTA and Citrate Vacuette vacutainer collection tubes were provided by Greiner Bio-One. For liquid chromatography mass spectrometry, targeted analysis was performed using the Biocrates AbsoluteIDQ p180 kit with an ultra-high-performance liquid chromatography (UHPLC) coupled to a Q-Trap mass spectrometer (MS).

The team analyzed 189 metabolites using the same protocol for quantitative targeted metabolomics. The concentration levels were higher in serum than citrate and EDTA, in particular for amino acids and biogenic amines. For amino acids, the average value of the relative difference was 7% higher in serum than EDTA and 6% higher in serum than citrate. For biogenic amines the average value of the relative difference was 11% higher in serum than EDTA and 15% higher in serum than citrate. The investigators also demonstrated that blank EDTA vacutainer tubes contain a significant amount of sarcosine. Finally, they compared the metabolome of young people against elderly subjects and found that the highest number of metabolites significantly changing with age was detected in serum.

The authors concluded that serum samples provide higher sensitivity for biomarker discovery studies. Due to the presence of spurious amount of sarcosine in vacutainer EDTA tubes, plasma EDTA is not suitable for studies requiring accurate quantification of sarcosine. The study was published online on August 13, 2018, in the journal Clinica Chimica Acta.

Related Links:
Institute for Biomedicine

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.