We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
INTEGRA BIOSCIENCES AG

Download Mobile App




Salivary Glucose Levels Measured by Biochip Sensor

By LabMedica International staff writers
Posted on 18 Jun 2014
A new biochip sensor has been developed that can selectively measure concentrations of glucose in a complex solution similar to human saliva.

The new chip makes use of a series of specific chemical reactions combined with plasmonic interferometry which is a means of detecting chemical signature of compounds using light. More...
The device is sensitive enough to detect differences in glucose concentrations that amount to just a few thousand molecules in the sampled volume.

Scientists at Brown University (Providence, RI, USA) exploited the synergistic advantage of combining plasmonic interferometry with an enzyme-driven dye assay that yields an optical sensor capable of detecting glucose in saliva with high sensitivity and selectivity. The biochip is made from a 2.54 x 2.54-cm piece of quartz coated with a thin layer of silver. Etched in the silver are thousands of nanoscale interferometers, tiny slits with a groove on each side. The grooves measure 200 nm wide and the slit is 100 nm wide.

When a liquid is deposited on the chip, the light and the surface plasmon waves propagate through that liquid before they interfere with each other. That alters the interference patterns picked up by the detectors, depending on the chemical makeup of the liquid. The scientists added microfluidic channels to the chip to introduce two enzymes that react with glucose in a very specific way. The first enzyme, glucose oxidase, reacts with glucose to form a molecule of hydrogen peroxide. This molecule then reacts with the second enzyme, horseradish peroxidase, to generate a molecule called resorufin, which can absorb and emit red light, thus coloring the solution. The team could then tune the interferometers to look for the red resorufin molecules.

The team tested its combination of dye chemistry and plasmonic interferometry by looking for glucose in artificial saliva, a mixture of water, salts and enzymes that resembles the real human saliva. They found that they could detect resorufin in real time with great accuracy and specificity. They were able to detect changes in glucose concentration of 0.1 μM/L, which is 10 times the sensitivity that can be achieved by interferometers alone. The proposed device is highly sensitive and highly specific for glucose sensing in picoliter volumes, across the physiological range of glucose concentrations found in human saliva, which is 20 μM–240 μM.

Domenico Pacifici, PhD, an assistant professor of engineering, and who led the study, said, “We have demonstrated the sensitivity needed to measure glucose concentrations typical in saliva, which are typically 100 times lower than in blood. Now we are able to do this with extremely high specificity, which means that we can differentiate glucose from the background components of saliva.” The study was published in the June 2014 edition of the journal Nanophotonics.

Related Links:

Brown University


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Automatic Hematology Analyzer
CF9600
POC Immunoassay Analyzer
Procise DX
New
Neurofilament Light Chain Assay
Lumipulse G NfL Blood
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The Avantect Pancreatic Cancer Test combines epigenomic, genomic, and glycan biomarkers with machine learning to detect pancreatic cancer-associated signals in blood (Photo courtesy of ClearNote Health)

Multiomic Blood Test Supports Noninvasive Monitoring and Subtyping in Pancreatic Cancer

Pancreatic ductal adenocarcinoma remains difficult to detect early and monitor during treatment, particularly in patients with homologous recombination defects. Clinicians also have limited noninvasive... Read more

Immunology

view channel
Image: Although many people harbor latent Epstein-Barr virus (EBV), growing evidence has linked the virus to MS pathobiology (Image Credit: Adobe Stock)

Blood EBV Activity Biomarkers May Predict Multiple Sclerosis Relapse Months Ahead

Predicting relapse in multiple sclerosis (MS) remains difficult, limiting opportunities for timely intervention and monitoring. Although many people harbor latent Epstein-Barr virus (EBV), growing evidence... Read more

Microbiology

view channel
Image: Graphical Abstract (Jose A. Céspedes, Maria I. Montañez, Isabel M. Jiménez, et al. Magnetic nanoparticles enable clinically relevant in vitro diagnosis of beta-lactam allergy. Materials Today Bio (2026). DOI: 10.1016/j.mtbio.2026.103356)

Magnetic Nanoparticles Enable More Sensitive Beta-Lactam Allergy Testing

Penicillin allergy labels are common in clinical practice, yet many are incorrect and can lead to suboptimal antibiotic choices. Although 8%–25% of people report a penicillin allergy, only 1%–10% are truly... Read more

Pathology

view channel
Image: A new study demonstrates that vascular features in colorectal tumors could serve as prognostic biomarkers of disease outcome. (Image Credit: iStock)

Tumor Blood Vessel Features May Help Predict Colorectal Cancer Survival

Colorectal cancer outcomes vary widely, and tumor biology remains a key determinant of prognosis. Because neoplasms depend on a vascular supply, differences in intratumoral vessels may influence survival.... Read more

Technology

view channel
Image: ADLM recommends that emerging AI tools follow the same professional oversight, quality, validation, and monitoring standards as traditional clinical testing within CLIA’s existing framework (Image Credit: Adobe Stock)

ADLM Calls for CLIA Updates to Support Safe AI Use in Laboratory Medicine

Clinical laboratories increasingly use artificial intelligence to verify, interpret, and report results, but safeguards under the Clinical Laboratory Improvement Amendments (CLIA) were designed in 1992.... Read more

Industry

view channel
Image Credit: Adobe Stock

Mayo Clinic and Thermo Fisher Launch Multi-Omics Venture to Identify Early Disease Signals

Many diseases begin developing years before symptoms emerge, making early detection difficult for healthcare systems and clinical laboratories. Linking molecular changes with longitudinal health data could... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.