Better Blood Glucose Monitor Evaluated for Burn Care

By LabMedica International staff writers
Posted on 18 Sep 2013
Glucose monitoring systems (GMS) with an autocorrect feature can detect red blood cells hematocrit, vitamin C, and other common interferents in burn patients' blood.

Traditional hospital laboratory testing uses plasma samples devoid of red blood cells, so it remains the most accurate method for measuring blood glucose levels. More...
However, the newer autocorrecting devices use less blood, and produce results in just five seconds, as opposed to approximately 10 to 20 minutes for laboratory testing.

A multidisciplinary team at the University of California (Davis, CA, USA) conducted a prospective, observational study followed by a pilot randomized controlled trial. Sixty remnant arterial blood samples were collected to evaluate hematocrit and ascorbic acid effects on accuracy paired against a plasma glucose reference. Another 12 patients were enrolled for a control trial.

The team compared an autocorrecting modified glucose oxidase-based GMS (GMS1; StatStrip Glucose; Nova Biomedical, Waltham, MA, USA) versus a noncorrecting glucose dehydrogenase-based GMS (GMS2; AccuChek Advantage; Roche Diagnostics, Indianapolis, IN, USA). GMS1 incorporates a novel four-well gold biosensor that autocorrects for hematocrit, oxidizing substances, and oxygen tension effects. GMS2 is the current device used for routine care at the institution. The hospital clinical chemistry laboratory analyzer (Synchron LX20, Beckman Coulter; Brea, CA, USA) served as the plasma glucose-reference method. All three systems measure glucose via electrochemical techniques.

An inversely proportional relationship between GMS2 results and hematocrit was observed. In contrast, GMS1 was unaffected by hematocrit. Automatic GMS hematocrit correction reduced glycemic variability, insulin rates, and hypoglycemic events. However, patients at risk of hematocrit and vitamin C interferences, especially burn patients receiving high dose vitamin C therapy, will be tested with the hospital's clinical chemistry laboratory analyzer for glucose levels in the future.

Nam K. Tran, PhD, MS, the lead author said, “Many glucose monitoring systems may not adequately correct for interferents in the blood of burn patients. As a result, an inaccurate reading increases the potential for an insulin overdose. Our study showed that using a device that autocorrects for interferents can produce more accurate blood glucose measurements, which can improve insulin dosing and glucose control." The study was published on September 2, 2103, in the Journal of Burn Care Research.

Related Links:

University of California, Davis
Roche Diagnostics
Nova Biomedical



Gold Member
Quantitative POC Immunoassay Analyzer
EASY READER+
Collection and Transport System
PurSafe Plus®
Laboratory Software
ArtelWare
ESR Analyzer
TEST1 2.0
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: New research points to protecting blood during radiation therapy (Photo courtesy of 123RF)

Pioneering Model Measures Radiation Exposure in Blood for Precise Cancer Treatments

Scientists have long focused on protecting organs near tumors during radiotherapy, but blood — a vital, circulating tissue — has largely been excluded from dose calculations. Each blood cell passing through... Read more

Technology

view channel
Image: Conceptual design of the CORAL capsule for microbial sampling in the small intestine (H. Mohammed et al., Device (2025). DOI: 10.1016/j.device.2025.100904)

Coral-Inspired Capsule Samples Hidden Bacteria from Small Intestine

The gut microbiome has been linked to conditions ranging from immune disorders to mental health, yet conventional stool tests often fail to capture bacterial populations in the small intestine.... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.