We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

PERKIN ELMER CORPORATION

PerkinElmer provides detection technologies to detect and identify diseases, imaging technologies to help visualize s... read more Featured Products: More products

Download Mobile App




Simple Colorimetric Assay Determines Human Mercaptalbumin Concentration

By LabMedica International staff writers
Posted on 30 Jun 2022
Print article
Image: VICTOR Nivo Multimode Microplate Reader (Photo courtesy of PerkinElmer)
Image: VICTOR Nivo Multimode Microplate Reader (Photo courtesy of PerkinElmer)

Human serum albumin (HAS) can take on two forms, mercaptalbumin (HMA) or non-mercaptalbumin (HNA), depending on the redox status of its Cys34. The ratio of HMA and HNA is considered to be a novel biomarker of oxidative stress.

The majority of studies on the redox state of HSA utilize high performance liquid chromatography (HPLC). Several recent studies have also employed mass spectrometry, which yields a higher resolution, thus allowing for finer distinctions between molecular structures. A handful of studies have explored alternative approaches using simple dye-based assays.

Clinical Laboratorians at The University of Tokyo Hospital (Tokyo, Japan) collaborated with colleagues at Nitto Boseki Co. Ltd., (Kawasaki, Japan) measured the concentrations of HMA in serum samples from 36 healthy subjects based on absorption changes of Michler's Hydrol. Michler's Hydrol (4,4′-Bis(dimethylamino)benzhydrol) is a blue dye with a maximum absorption at 612 nm, and its absorption decreases when it reacts with a thiol group.

After processing the samples, the solution was incubated further at room temperature for 20 minutes and absorbance at 612 nm (A612) was measured by a 96-well plate Nivo 3F microplate reader (PerkinElmer, Waltham, MA, USA). To evaluate the performance of the assays, the correlation was determined by a linear regression between the HMA concentrations obtained by Michler's Hydrol assay and corresponding reference concentrations obtained by HPLC and Bromocresol purple (BCP) assays.

The scientists reported that HMA concentrations obtained by Michler's Hydrol assay were highly correlated (r2 = 0.97) with reference values obtained by HPLC (HMA %) and BCP assay (total albumin). The HNA% obtained by Michler's Hydrol and BCP assays combined also gave a good correlation (r2 = 0.96) and a small deviation (average 2.4%) with respect to HPLC as a reference method. The use of the HMA/HNA ratio, which is a function of oxidation of Cys34, is considered a potential biomarker to assess the severity of chronic diseases for which oxidative stress is a significant etiological manifestation.

The authors concluded that the concentrations of HMA in human serum can be measured by Michler's Hydrol assay, which is based on an approximation of HMA concentrations with Michler's Hydrol's colorimetric changes mainly due to thiols. The assay accuracy was significantly improved by pre-incubation of a subset of the samples with an alkylating agent (iodoacetamide) and subtracting their absorption from the absorption of corresponding samples without alkylation. Proportions of HMA and HNA were also obtained by combining Michler's Hydrol assay and the BCP assay (for total albumin concentration). The results correlated well with HPLC, which has been established as a standard method for HMA/HNA measurement. The study was published on June 8, 2022 in the journal Practical Laboratory Medicine.

Related Links:
The University of Tokyo Hospital
Nitto Boseki Co. Ltd
PerkinElmer

 

Gold Member
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Verification Panels for Assay Development & QC
Seroconversion Panels
New
TRAcP 5b Assay
TRAcP 5b (BoneTRAP) Assay
New
Cytomegalovirus Real-Time PCR Test
Quanty CMV Virus System

Print article

Channels

Clinical Chemistry

view channel
Image: QIP-MS could predict and detect myeloma relapse earlier compared to currently used techniques (Photo courtesy of Adobe Stock)

Mass Spectrometry-Based Monitoring Technique to Predict and Identify Early Myeloma Relapse

Myeloma, a type of cancer that affects the bone marrow, is currently incurable, though many patients can live for over 10 years after diagnosis. However, around 1 in 5 individuals with myeloma have a high-risk... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.