We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
ZeptoMetrix an Antylia scientific company

Roche Diagnostics

Develops, manufactures, and markets a wide range of in vitro diagnostic systems, instruments, reagents, and tests read more Featured Products: More products

Download Mobile App




Methods for Intra-Erythrocyte Magnesium and Its Determinants Compared

By LabMedica International staff writers
Posted on 15 Oct 2020
Print article
Image Some of the components of the cobas 8000 modular analyzer series (Photo courtesy of Roche).
Image Some of the components of the cobas 8000 modular analyzer series (Photo courtesy of Roche).
Magnesium is the second most abundant intracellular cation and is essential for regulation of many functions within the cell, including modulation of ion channels, protein synthesis and energy metabolism.

Several laboratory tests to assess cellular magnesium concentrations in the human body have been evaluated, of which measurements in leukocytes generally correlate well with other magnesium pools, including skeleton, vascular smooth muscle and cardiac muscle.

Medical scientists at the University Medical Center Groningen (Groningen, the Netherlands) and their associates analyzed both urine and blood from 1,699 participants in a cohort study. The overall, mean age of the cohort was 51.0 ± 13.4 years, 57.5% were female, 36.0% were non-smoker and 11.9% non-drinker.

Plasma glucose was measured routinely on a Cobas 8000 platform (Roche, Mannheim, Germany) using a hexokinase UV test. Total cholesterol was measured using an enzymatic colorimetric assay, high-density lipoprotein cholesterol using a homogeneous enzymatic colorimetric assay, low-density lipoprotein cholesterol using a direct measurement, homogeneous enzymatic colorimetric assay, and triglycerides using a enzymatic colorimetric assay, not glycerol blanked, all measured routinely on a Cobas 8000.

The plasma magnesium concentration was also assessed using a colorimetric assay on a Cobas 8000. The colorimetric assay is based on the complex formation between magnesium ions and xylidyl blue in an alkaline solution (tris(hydroxymethyl)-aminomethane/6-aminocaproic acid buffer), forming a purple diazonium salt. EDTA whole blood samples were collected between August 2017 until December 2017. One aliquot sample was prepared for indirect intra-erythrocyte magnesium (iIEM) and one for direct intra-erythrocyte magnesium (dIEM). A validated inductively coupled plasma mass spectrometry (ICP-MS) method was used to determine magnesium in whole blood (for iIEM) and washed erythrocytes (for dIEM).

The investigators reported that the mean dIEM and iIEM were 0.20 ± 0.04 mmol/1012 cells and 0.25 ± 0.04 mmol/1012 cells, respectively. The mean plasma magnesium was 0.85 ± 0.06 mmol/L and mean urinary magnesium excretion was 4.85 ± 1.76 mmol/24-h. They found a strong correlation between dIEM and iIEM. Passing-Bablok regression analyses showed an intercept of 0.015 (95% CI: 0.005; 0.023) and a slope of 1.157 (95% CI: 1.109; 1.210). In linear regression analyses, plasma levels of total- and LDL -cholesterol, and triglycerides were positively associated dIEM, iIEM, and plasma magnesium, while glucose and HbA1c were inversely associated with plasma magnesium.

The authors concluded that there was a strong correlation between a direct and an indirect method for the assessment of IEM. The study indicated that iIEM can be used in practice, eliminating labor-intensive washing procedures and high costs required for direct methods. The study was published on September 11, 2020 in the journal Clinica Chimica Acta.




Gold Member
Chagas Disease Test
CHAGAS Cassette
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Benchtop Cooler
PCR-Cooler & PCR-Rack
New
Ultra-Low Temperature Freezer
iUF118-GX

Print article

Channels

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Technology

view channel
Image: Ziyang Wang and Shengxi Huang have developed a tool that enables precise insights into viral proteins and brain disease markers (Photo courtesy of Jeff Fitlow/Rice University)

Light Signature Algorithm to Enable Faster and More Precise Medical Diagnoses

Every material or molecule interacts with light in a unique way, creating a distinct pattern, much like a fingerprint. Optical spectroscopy, which involves shining a laser on a material and observing how... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.