Fragmented Red Blood Cell Measurement Automated

By LabMedica International staff writers
Posted on 02 Jul 2012
Print article
Image: Schistocytes in blood smear (Photo courtesy of Dr. Paulo H.O. Mourao).
Image: Schistocytes in blood smear (Photo courtesy of Dr. Paulo H.O. Mourao).
The laboratory diagnosis of thrombotic microangiopathies (TMA) or disorders that may mimic their features remains difficult.

The detection of schistocytes on the blood smear is a cornerstone finding to assess the diagnosis, but microscopic evaluation of schistocytes is still problematic with wide inter-observer variations.

Hematologists at the University Hospital (Nancy, France) conducted studies comparing automated and microscopic counts of Fragmented Red Blood Cells (FRC) and schistocytes. The data came from the day-to-day analysis of more than 90,000 peripheral blood (PB) samples for 10 years in four centers. More than 900 patients were examined because of a clinical suspicion of TMA and 17 samples were derived from preterm newborns who were supposed to give the highest FRC counts among nonpathologic samples.

FRC were counted by automated direct measurement using the two automated analyzers (ABCC): the ADVIA 120 analyzer (Siemens; Tarrytown, NY, USA) and the XE-2100 analyzer (Sysmex; Kobe, Japan). Schistocyte counting was carried out from May-Grünwald-Giemsa-stained PB smears. The reference range for FRC was less than 0.3% for the ADVIA and less than 0.5% for the Sysmex XE-2100.

The correlation coefficient for Siemens devices was around 0.7. The main problem resulted from an overestimation of FRC as compared to schistocytes from 0.4% to 0.5% for a count of schistocyte ranging from 0% to 1.5%. Conversely, the scientists observed an underestimation of FRC as compared to schistocytes subsequent to this 1.5% threshold. For the Sysmex XE-2100 counter, the overestimation of the FRC was more pronounced, at less 0.8%, and increased slightly with high schistocyte percentages. The presence of FRC below a threshold determined at 1% for both automated analyzers had a negative predictive value (PV) close to 100% to exclude the presence of schistocyte on the blood smear, but in relationship with a poor positive PV value.

The authors concluded that that systematic quantification of FRC might improve the laboratorians' ability to exclude samples with schistocytes. This should be especially useful among patients in whom TMA diagnosis is suspected. However, several limitations deserve consideration such as few false-negative FRC counts in a context of macrocytosis, great lack of specificity. Hence, a PB smear examination was still advised for the validation of the count if needed. The study was published on June 14, 2012, in the International Journal of Laboratory Hematology.

Related Links:

University Hospital
Siemens
Sysmex


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.