We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

QUIDEL

Develops, manufactures and markets rapid diagnostic tests at the point-ofcare (POC) that focus on infectious diseases... read more Featured Products: More products

Download Mobile App




Remote Dispensing of Emergency Release Red Blood Cells Assessed

By LabMedica International staff writers
Posted on 26 Oct 2022
Print article
Image: ORTHO VISION Max Analyzer is an instrument designed to automate in vitro immunohematology testing of human blood utilizing ID-MTS gel card technology (Photo courtesy of Ortho Clinical Diagnostics)
Image: ORTHO VISION Max Analyzer is an instrument designed to automate in vitro immunohematology testing of human blood utilizing ID-MTS gel card technology (Photo courtesy of Ortho Clinical Diagnostics)

Good transfusion practice requires meticulous attention to the correct identification of blood samples and the performance of pre-transfusion compatibility testing using validated procedures. Patients with acute bleeding are frequently transfused with emergency release (ER) group O red blood cells (RBCs).

There are several different approaches to address this need, but most employ the provision of group O RBCs to avoid ABO incompatibility. First, the RBCs can be packed into a container for urgent transportation to the intended site of transfusion, which is typically an emergency department (ED) or trauma bay.

Medical Transfusion Specialists at the Alpert Medical School of Brown University (Providence, RI, USA) examined records of patients who received ER RBCs over a 30-month period. In total, 935 patients received ER RBCs over this 30-month period, 816 at hospital A and 119 at hospital B; 527 (56%) were trauma patients, and 408 (44%) were non-trauma patients. Nurses accessing the refrigerator were required to give patient identification information, when known, prior to removal of the ER RBCs, allowing technologists the opportunity to check for previous serologic records and communicate directly with the ED if a serologic incompatibility was potentially present.

ABO typing, antibody screening, antibody panels, and antiglobulin cross-matches were routinely performed using a gel column agglutination technique on automated blood bank analyzers (Ortho Vision; Ortho Clinical Diagnostics, Raritan, NJ, USA) using reagents from the vendor. Ficin gel panels were used where required to clarify antibody identification. Phenotyping was performed using a tube technique (Bio-Rad, Hercules, CA, USA).

The team reported that total of 2,055 RBCs were removed from the electronically connected satellite refrigerator (ECSR): 1,855 from hospital A and 200 from hospital B, 1,847 of which were transfused, yielding an average of 2.0 units transfused per patient. Thirty (3.4%) patients had a serologic abnormality, and most patients with antibodies were female (18/30 or 60%). As expected, most of the antibodies with known specificity were Rhesus or Kell antibodies (35/43, 81%). In 15 cases, incompatible RBCs were interdicted. In six cases, the transfusion was considered urgent, and an acute hemolytic transfusion reaction (AHR) occurred in four of these six (overall 0.4%), including one fatal AHR due to anti-KEL1.

The authors concluded that their data was indicative of slightly higher rates of AHR than previously reported, which is possibly related to the inclusion of a large number of non-trauma patients, and the prospective active evaluation of recipients of incompatible RBCs. Given the frequency of anti-K, they believe a policy of storing only KEL1-negative RBCs in ED refrigerators and that the use of ECSRs in emergency departments with a high volume of ER RBCs are useful steps to mitigate the risk inherent in the practice of ER RBC transfusion. The study was published in the October 2022 issue of the American Journal of Clinical Pathology.

Related Links:
Alpert Medical School of Brown University 
Ortho Clinical Diagnostics 
Bio-Rad 

Gold Member
Troponin T QC
Troponin T Quality Control
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Creatine Kinase-MB Assay
CK-MB Test
New
TRAcP 5b Assay
TRAcP 5b (BoneTRAP) Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The tiny clay-based materials can be customized for a range of medical applications (Photo courtesy of Angira Roy and Sam O’Keefe)

‘Brilliantly Luminous’ Nanoscale Chemical Tool to Improve Disease Detection

Thousands of commercially available glowing molecules known as fluorophores are commonly used in medical imaging, disease detection, biomarker tagging, and chemical analysis. They are also integral in... Read more

Immunology

view channel
Image: The cancer stem cell test can accurately choose more effective treatments (Photo courtesy of University of Cincinnati)

Stem Cell Test Predicts Treatment Outcome for Patients with Platinum-Resistant Ovarian Cancer

Epithelial ovarian cancer frequently responds to chemotherapy initially, but eventually, the tumor develops resistance to the therapy, leading to regrowth. This resistance is partially due to the activation... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Delivers Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Pathology

view channel
Image: The ready-to-use DUB enzyme assay kits accelerate routine DUB activity assays without compromising data quality (Photo courtesy of Adobe Stock)

Sensitive and Specific DUB Enzyme Assay Kits Require Minimal Setup Without Substrate Preparation

Ubiquitination and deubiquitination are two important physiological processes in the ubiquitin-proteasome system, responsible for protein degradation in cells. Deubiquitinating (DUB) enzymes contain around... Read more

Technology

view channel
Image: The HIV-1 self-testing chip will be capable of selectively detecting HIV in whole blood samples (Photo courtesy of Shutterstock)

Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples

As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.