A magnetic nanoparticle-based technique has been developed to directly detect microRNA (miRNA) in unprocessed whole blood samples in about thirty minutes. More...
Currently scientists use quantitative reverse-transcription polymerase chain reaction (qRT-PCR) to profile miRNA due to its usually high specificity and sensitivity.

Although qRT-PCR produces reliable results, scientists have noted that it does not detect miRNA directly in whole blood. Instead, scientists perform a lengthy process where they must isolate and purify RNA, and then synthesize complementary DNA (cDNA) to measure miRNA expression. The first human disease known to be associated with miRNA deregulation was chronic lymphocytic leukemia.

Scientists at the University of New South Wales (Sydney, Australia) modified the surface of the gold-coated magnetic nanoparticles (Au@MNPs) with a probe DNA sequence complementary to miR-21 and marked it with a blue redox label. The team then added excess network of modified Au@MNPs by probe DNA (DNA-Au@NMPs) to the analyte solution. After 30 minutes, the team magnetically separated the Au@MNPs from the solution and washed away unhybridized sequences. They then collected the Au@MNPs on the surface of a gold microelectrode using a magnet. The team removed the magnet and applied 10 cycles of square-wave voltammetry between 200 and 500 megaVolts, with a pulse amplitude of 20 megavolts and frequency of 2 hertz. The team then used stable peak currents obtained before and after hybridization to measure the amount of analyte.

To examine the electrochemical tool's limit of detection and range of its sensor, the team prepared different concentrations of miR-21 in either phosphate buffered saline (PBS), undiluted human serum, or 50% whole human blood. The group measured a change in the current after 30 minutes of exposure to the miR-21 solutions within the concentration range of 10 attomolar to 1 nanomolar. In order to validate the electrochemical tool, the team used it to analyze miR-21 levels in a pool of other RNA sequences from the total RNA extracted from human lung cancer cells (A459) and exosomes. After treating the samples with an miR-21 inhibitor, the team still detected levels of miR-21 in exosomes eight times lower than the factor of 0.4 in their parental cells.

Using the DNA-Au@MNP-based electrochemical sensor, the team found that the concentration of miR-21 molecules in rapidly growing cancers was higher than those in the "no-control" group. The group also noted that the electrochemical assay had less variability than qRT-PCR. John Gooding, D. Phil, a chemistry professor and senior author of the study, said, “This tool would be especially useful for low levels of certain proteins and molecules, as we could potentially not only diagnose a patient's condition, but also look at treatment efficacy or the potential relapse of a condition like cancer. The study was published on August 27, 2018, in the journal Nature Nanotechnology.

Related Links:
University of New South Wales


Gold Member
Automatic Hematology Analyzer
DH-800 Series
Collection and Transport System
PurSafe Plus®
Sample Transportation System
Tempus1800 Necto
Pipette
Accumax Smart Series
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The genomic test measures eight gene activities in a melanoma tumor and combines this data with patient factors like age and tumor thickness (Photo courtesy of 123RF)

Genomic Test Could Reduce Lymph Node Biopsy Surgery in Melanoma Patients

Accurately determining whether melanoma has spread to the lymph nodes is crucial for guiding treatment decisions, yet the standard procedure—sentinel lymph node biopsy—remains invasive, costly, and unnecessary... Read more

Hematology

view channel
Image: New evidence shows viscoelastic testing can improve assessment of blood clotting during postpartum hemorrhage (Photo courtesy of 123RF)

Viscoelastic Testing Could Improve Treatment of Maternal Hemorrhage

Postpartum hemorrhage, severe bleeding after childbirth, remains one of the leading causes of maternal mortality worldwide, yet many of these deaths are preventable. Standard care can be hindered by delays... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.