Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Glutaraldehyde Test Evaluated for Rapid Tuberculosis Diagnosis

By LabMedica International staff writers
Posted on 16 Nov 2017
Tuberculosis (TB) remains one of the leading causes of morbidity and mortality worldwide and the primary method for controlling TB is the rapid and accurate identification of infected individuals.

Smear examination and culture of Mycobacterium tuberculosis bacilli have remained the gold standard, but the sensitivity of the direct smear examination of sputum, however, is low, while culture is time-consuming, labo¬rious and not always available. More...
Immune response exploitation represents one of the main methods used for early TB diagnosis.

Microbiologists at the University Hospital Farhat Hached (Sousse, Tunisia) determined the diagnostic value of a glutaraldehyde test (GT) in pulmonary tuberculosis (PTB) and extra-pulmonary tuberculosis (EPTB) and to assess its performance compared with light-emitting diode fluorescence microscopy (LED-FM). This study included 272 specimens, 176 suspected PTB specimens and 96 suspected EPTB specimens. Of the 272 patients, 98 patients had TB infection confirmed by culture (64 PTB cases and 34 EPTB cases), and 174 patients had no TB infection. The gold standard technique (culture) was used as reference to verify the GT’s performance.

Sputum, extra-respiratory and blood samples for the GT were preferably collected on the same day. All specimens were subjected to smear examination, and each specimen was inoculated into Lowenstein-Jensen (LJ) and Coletsos culture media for up to eight weeks. Positive growth was confirmed by Ziehl-Neelsen staining, and mycobacterial isolates were identified using conventional biochemical techniques. The GT kit, ANDA-TB GA test case finding was used and a gelification time less than 10 minutes denotes a possible TB infection.

The team reported that the GT showed a high sensitivity (96.9%) and specificity (82.1%) for PTB with a good positive predictive value (PPV = 75.6%) and negative predictive value (NPV = 97.9%). For EPTB, the GT showed a sensitivity of 91.2% and a specificity of 77.4%, with PPV = 68.9% and NPV = 94.1%. LED-FM had lower sensitivities for PTB (65.6%) and EPTB (42.1%) and an excellent specificity of 100%, with PPV = 100% and NPV = 100%.

The authors concluded that the GT is rapid, easy, simple and cost-effective and does not require qualified personnel with a specific background or sophisticated equipment like molecular biology or mycobacterium-specific genotyping techniques. These qualities make the GT attractive for use in low- and high-income countries in addition to other conventional methods, particularly culture, which continues to be the gold standard. The study was published in the November 2017 issue of the journal Memórias do Instituto Oswaldo Cruz.

Related Links:
University Hospital Farhat Hached



Gold Member
Quantitative POC Immunoassay Analyzer
EASY READER+
POC Helicobacter Pylori Test Kit
Hepy Urease Test
New
Pipette
Accumax Smart Series
New
Specimen Radiography System
TrueView 200 Pro
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: New research points to protecting blood during radiation therapy (Photo courtesy of 123RF)

Pioneering Model Measures Radiation Exposure in Blood for Precise Cancer Treatments

Scientists have long focused on protecting organs near tumors during radiotherapy, but blood — a vital, circulating tissue — has largely been excluded from dose calculations. Each blood cell passing through... Read more

Immunology

view channel
Image: The test could streamline clinical decision-making by identifying ideal candidates for immunotherapy upfront (Xiao, Y. et al. Cancer Biology & Medicine July 2025, 20250038)

Blood Test Predicts Immunotherapy Efficacy in Triple-Negative Breast Cancer

Triple-negative breast cancer (TNBC) is an aggressive subtype lacking targeted therapies, making immunotherapy a promising yet unpredictable option. Current biomarkers such as PD-L1 expression or tumor... Read more

Pathology

view channel
image: Researchers Marco Gustav (right) and MD Nic G. Reitsam (left) discuss the study data (Photo courtesy of Anja Stübner/EKFZ)

AI Model Simultaneously Detects Multiple Genetic Colorectal Cancer Markers in Tissue Samples

Colorectal cancer is a complex disease influenced by multiple genetic alterations. Traditionally, studies and diagnostic tools have focused on predicting only one mutation at a time, overlooking the interplay... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.