Novel Procalcitonin Immunoassay Analytically Evaluated

By LabMedica International staff writers
Posted on 25 Jan 2017
The exact definition of sepsis has changed considerably over time, and remains controversial. More...
This is probably due to the fact that sepsis develops as a continuum of severity, ranging from local infection, through bloodstream propagation to septic shock.

Due to the steadily increasing use of procalcitonin (PCT) measurement for diagnosis and management of bacterial infections, the number of PCT immunoassays available on the diagnostic market has increased in recent years, with automated immunoassays replacing the former manual techniques.

Clinical biochemists at the University of Verona carried out an analytical evaluation of a two-step sandwich immunoassay for PCT in human serum and plasma. This analytical evaluation encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, intra- and inter-assay imprecision, confirmation of linearity and a comparison with the ELFA immunoassay Vidas BRAHMS PCT.

The assay evaluated was the Lumipulse G BRAHMS PCT immunoassay adapted to be used on the LUMIPULSE G1200 system. The assay is based on ChemiLuminescent Enzyme Immunoassay (CLEIA) technology. Briefly, the PCT molecules present in the test sample bind to monoclonal anti-PCT mouse antibodies and to capture anti-calcitonin mouse antibodies coated on polystyrene beads, thus generating stable immune complexes and the luminescence is monitored at 477 nm. The assay displays an analytical sensitivity of 0.0048 ng/mL, a functional sensitivity of 0.0079 ng/mL and linearity comprised between 0.02 to 85.1 ng/mL and results are available in 30 minutes.

The LOB, LOD and functional sensitivity were 0.001 ng/mL, 0.0016 ng/mL and 0.008 ng/mL, respectively. The total analytical imprecision was found to be 2.1% and the linearity was excellent in the range of concentrations between 0.006 to 75.5 ng/mL. The correlation coefficient with Vidas BRAHMS PCT was 0.995. The diagnostic agreement was 100% at 0.5 ng/mL, 97% at 2.0 ng/mL and 95% at 10 ng/mL, respectively.

The authors concluded that the results of the evaluation of Lumipulse G BRAHMS PCT demonstrate that this technique exhibits excellent analytical performance, among the best of the methods currently available on the diagnostic market for routine PCT measurement. However, the significant bias shown by comparing the two immunoassays studied emphasizes that longitudinal patient monitoring should be always performed using the same immunoassay. The study was published on December 1, 2016, in the journal Practical Laboratory Medicine.


New
Gold Member
Ketosis and DKA Test
D-3-Hydroxybutyrate (Ranbut) Assay
Portable Electronic Pipette
Mini 96
New
Homocysteine Quality Control
Liquichek Homocysteine Control
New
CBM Analyzer
Complete Blood Morphology (CBM) Analyzer
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: A schematic illustrating the coagulation cascade in vitro (Photo courtesy of Harris, N., 2024)

ADLM’s New Coagulation Testing Guidance to Improve Care for Patients on Blood Thinners

Direct oral anticoagulants (DOACs) are one of the most common types of blood thinners. Patients take them to prevent a host of complications that could arise from blood clotting, including stroke, deep... Read more

Microbiology

view channel
Image: EBP and EBP plus have received FDA 510(k) clearance and CE-IVDR Certification for use on the BD COR system (Photo courtesy of BD)

High-Throughput Enteric Panels Detect Multiple GI Bacterial Infections from Single Stool Swab Sample

Gastrointestinal (GI) infections are among the most common causes of illness worldwide, leading to over 1.7 million deaths annually and placing a heavy burden on healthcare systems. Conventional diagnostic... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.