Urinary Hydration Markers Tested for Storage Condition Validity

By LabMedica International staff writers
Posted on 27 Aug 2019
Fluid balance is an aspect of the homeostasis of organisms in which the amount of water in the organism needs to be controlled, via osmoregulation and behavior, such that the concentrations of electrolytes in the various body fluids are kept within healthy ranges.

The human kidneys will normally adjust to varying levels of water intake. More...
The kidneys will require time to adjust to the new water intake level. This can cause someone who drinks a lot of water to become dehydrated more easily than someone who routinely drinks less. Analysis of urine specimens is widely utilized to determine day-to-day hydration status in individuals as well as for other markers of health.

Scientists at the University of North Carolina at Greensboro (Greensboro, NC, USA) enrolled eight males and 13 females (mean ± SD; age, 24 ± 5 years; body mass, 68.9 ± 24.2 kg; height, 160.2 ± 32.1 cm) without a history of renal disease or currently taking any medications or supplements known to affect the accuracy of urinary hydration markers. Participants provided a 24 hour urine sample in a clean container with each urine sample being separate into four separate containers, two in each of the following temperatures: 7 °C and 22 °C. One specimen container at each temperature was either sealed using the manufacturers cap (single sealed, SS) or the manufacturers cap plus laboratory wrapping film (double sealed, DS).

Each sample was analyzed after 1, 2, 3, 7 and 10 days. Urine samples were assessed for urine osmolality (UOSMO), urine specific gravity (USG), and urine color (UCOL). UOSMO was stable at 7 °C for two days and three days for single sealed and double sealed containers, respectively. UOSMO was determined via freezing point depression with a 3320 osmometer. USG was measured using an optical refractometer that was accurate to ±0.001 AU and had a resolution of 0.0001. UCOL was measured by comparing each urine sample to an 8-point urine color chart where the sample was held against a white background in a well-lit room.

The team reported that USG measures were stable for singled sealed and double sealed for up to ten days when stored at 22 °C. UCOL measures were maintained for up to three days in all storage methods. For refrigerated samples, UOSMO measures for samples stored in SS containers became significantly elevated three days following baseline measures, whereas UOSMO measures for samples stored in DS containers became significantly elevated seven days following baseline measures. Conversely to UOSMO, USG measures were significantly elevated in SS and DS samples stored at 7 °C beginning one day following baseline measures, compared to SS and DS samples stored at 20 °C.

The authors concluded that to achieve optimal results, it is recommended that 24-hour urine samples are assessed immediately for the respective hydration markers being analyzed. If immediate analysis is unavailable, such as in the case of field based or longitudinal research, it is recommended that 24-hour urine samples are stored in a refrigerated environment and hydration markers (UOSMO and UCOL) be assessed within 48 hours. The study was published on August 5, 2019, in the journal PLOS ONE.

Related Links:
University of North Carolina at Greensboro


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
βeta-Hydroxybutyrate Reagent
β-Hydroxybutyrate LiquiColor®
Drug Testing Assays
Atellica DT 250 Analyzer
Gold Member
Platelet Function Analyzer
PL-12
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image Credit: Adobe Stock

AI in Cancer Diagnosis and Molecular Testing Takes Center Stage at AMP 2026

Artificial intelligence (AI) is increasingly being integrated into molecular diagnostics, offering new approaches to interpreting complex genetic information, classifying cancers, and optimizing laboratory testing.... Read more

Immunology

view channel
Image: The panel expands Cepheid’s respiratory testing portfolio on the GeneXpert platform, offering laboratories greater flexibility in selecting tests based on clinical needs. (Photo courtesy of Cepheid)

Multiplex PCR Test Gains CE Marking to Support Respiratory Infection Diagnosis

Acute respiratory infections often present with overlapping symptoms, making it difficult to distinguish between viral and bacterial causes. Seasonal surges of influenza-like illness in Europe further... Read more

Microbiology

view channel
Image: Graphical Abstract (Matthew A Butzler, Jennifer L Reed, Alaina M Olson, et al. Development of a Rapid Automated Point-of-Care Test for Mycobacterium tuberculosis Detection from Tongue Swabs and Sputum Specimens on the DASH® Rapid PCR System, Open Forum Infectious Diseases, 2026; https://doi.org/10.1093/ofid/ofag706)

Rapid Point-of-Care Test Detects Tuberculosis from Tongue Swab and Sputum

Tuberculosis remains a major infectious disease challenge, particularly in regions with limited access to diagnostic testing and treatment. Diagnosis can be time-consuming, and collecting sputum samples... Read more

Pathology

view channel
Image Credit: Adobe Stock

New Training Approach Helps AI Distinguish Neighboring Cells in Tissue

Artificial intelligence (AI) can assist with identifying cells in digital pathology images, but densely packed tissue remains difficult to analyze. Neighboring cells may be merged, counted twice, or missed,... Read more

Industry

view channel
Image: The TOMR trial uses Signatera-guided MRD testing to identify high-risk patients for curative-intent treatment.

Natera and Incyte Collaborate on MRD-Guided Colorectal Cancer Treatment Study

Natera (Austin, TX, USA) has entered into a clinical collaboration with Incyte (Wilmington, DE, USA) for a Phase II study evaluating molecular residual disease (MRD)-guided treatment in colorectal cancer.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.