Urinary Hydration Markers Tested for Storage Condition Validity

By LabMedica International staff writers
Posted on 27 Aug 2019
Fluid balance is an aspect of the homeostasis of organisms in which the amount of water in the organism needs to be controlled, via osmoregulation and behavior, such that the concentrations of electrolytes in the various body fluids are kept within healthy ranges.

The human kidneys will normally adjust to varying levels of water intake. More...
The kidneys will require time to adjust to the new water intake level. This can cause someone who drinks a lot of water to become dehydrated more easily than someone who routinely drinks less. Analysis of urine specimens is widely utilized to determine day-to-day hydration status in individuals as well as for other markers of health.

Scientists at the University of North Carolina at Greensboro (Greensboro, NC, USA) enrolled eight males and 13 females (mean ± SD; age, 24 ± 5 years; body mass, 68.9 ± 24.2 kg; height, 160.2 ± 32.1 cm) without a history of renal disease or currently taking any medications or supplements known to affect the accuracy of urinary hydration markers. Participants provided a 24 hour urine sample in a clean container with each urine sample being separate into four separate containers, two in each of the following temperatures: 7 °C and 22 °C. One specimen container at each temperature was either sealed using the manufacturers cap (single sealed, SS) or the manufacturers cap plus laboratory wrapping film (double sealed, DS).

Each sample was analyzed after 1, 2, 3, 7 and 10 days. Urine samples were assessed for urine osmolality (UOSMO), urine specific gravity (USG), and urine color (UCOL). UOSMO was stable at 7 °C for two days and three days for single sealed and double sealed containers, respectively. UOSMO was determined via freezing point depression with a 3320 osmometer. USG was measured using an optical refractometer that was accurate to ±0.001 AU and had a resolution of 0.0001. UCOL was measured by comparing each urine sample to an 8-point urine color chart where the sample was held against a white background in a well-lit room.

The team reported that USG measures were stable for singled sealed and double sealed for up to ten days when stored at 22 °C. UCOL measures were maintained for up to three days in all storage methods. For refrigerated samples, UOSMO measures for samples stored in SS containers became significantly elevated three days following baseline measures, whereas UOSMO measures for samples stored in DS containers became significantly elevated seven days following baseline measures. Conversely to UOSMO, USG measures were significantly elevated in SS and DS samples stored at 7 °C beginning one day following baseline measures, compared to SS and DS samples stored at 20 °C.

The authors concluded that to achieve optimal results, it is recommended that 24-hour urine samples are assessed immediately for the respective hydration markers being analyzed. If immediate analysis is unavailable, such as in the case of field based or longitudinal research, it is recommended that 24-hour urine samples are stored in a refrigerated environment and hydration markers (UOSMO and UCOL) be assessed within 48 hours. The study was published on August 5, 2019, in the journal PLOS ONE.

Related Links:
University of North Carolina at Greensboro


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Automated Clinical Chemistry Analyzer
Envoy 500+
New
MR-proADM Test
B•R•A•H•M•S MR-proADM KRYPTOR test
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: NTM are about 200 environmental bacteria found in soil and water that can cause chronic, tuberculosis-like lung infections but are distinct from the Mycobacterium tuberculosis complex (Image Credit: Adobe Stock)

Rapid CRISPR Test Identifies Nontuberculous Mycobacteria Species from Respiratory Samples

Chronic lung infections caused by nontuberculous mycobacteria (NTM) are increasingly recognized but frequently mistaken for tuberculosis, complicating diagnosis and care. These infections may affect as... Read more

Immunology

view channel
Image: Although many people harbor latent Epstein-Barr virus (EBV), growing evidence has linked the virus to MS pathobiology (Image Credit: Adobe Stock)

Blood EBV Activity Biomarkers May Predict Multiple Sclerosis Relapse Months Ahead

Predicting relapse in multiple sclerosis (MS) remains difficult, limiting opportunities for timely intervention and monitoring. Although many people harbor latent Epstein-Barr virus (EBV), growing evidence... Read more

Microbiology

view channel
Image: Graphical Abstract (Jose A. Céspedes, Maria I. Montañez, Isabel M. Jiménez, et al. Magnetic nanoparticles enable clinically relevant in vitro diagnosis of beta-lactam allergy. Materials Today Bio (2026). DOI: 10.1016/j.mtbio.2026.103356)

Magnetic Nanoparticles Enable More Sensitive Beta-Lactam Allergy Testing

Penicillin allergy labels are common in clinical practice, yet many are incorrect and can lead to suboptimal antibiotic choices. Although 8%–25% of people report a penicillin allergy, only 1%–10% are truly... Read more

Pathology

view channel
image Credit: iStock

Tumor Budding Grading May Predict Chemotherapy Benefit in Resected Lung Squamous Cancer

Outcomes after resection for lung squamous cell carcinoma (SqCC) vary substantially, and the uneven benefit of adjuvant chemotherapy complicates postsurgical treatment decisions. Pathologic markers that... Read more

Technology

view channel
Image: ADLM recommends that emerging AI tools follow the same professional oversight, quality, validation, and monitoring standards as traditional clinical testing within CLIA’s existing framework (Image Credit: Adobe Stock)

ADLM Calls for CLIA Updates to Support Safe AI Use in Laboratory Medicine

Clinical laboratories increasingly use artificial intelligence to verify, interpret, and report results, but safeguards under the Clinical Laboratory Improvement Amendments (CLIA) were designed in 1992.... Read more

Industry

view channel
Image: The acquisition adds Convergent Genomics’ UroAmp platform and proprietary urinary tumor DNA technology to Veracyte’s portfolio (Photo courtesy of Convergent Genomics)

Veracyte Acquisition Expands Urine-Based Bladder Cancer Monitoring Capabilities

Veracyte, Inc. has acquired Convergent Genomics, expanding its urology diagnostics offerings with the company’s UroAmp platform and proprietary urinary tumor DNA (utDNA) technology. UroAmp has been clinically... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.