We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Fluidigm

Fluidigm Corporation focuses on the most pressing needs in translational and clinical research, including cancer, imm... read more Featured Products: More products

Download Mobile App




Blood Test Monitors Relapsed Serous Ovarian Cancer

By LabMedica International staff writers
Posted on 09 Feb 2017
Print article
Image: The Biomark microfluidic system for polymerase chain reactions (Photo courtesy of Fluidigm).
Image: The Biomark microfluidic system for polymerase chain reactions (Photo courtesy of Fluidigm).
The development of blood biomarkers that can be used for early detection of cancer or to measure tumor burden and response to treatment is a major goal of translational cancer studies across all cancer types.

Circulating tumor DNA (ctDNA) carrying tumor-specific sequence alterations may provide a minimally invasive means to dynamically assess tumor burden and response to treatment in cancer patients.

Scientists at Cambridge University performed a retrospective analysis of serial plasma samples collected during routine clinical visits from 40 patients with high-grade serous ovarian carcinoma (HGSOC) undergoing heterogeneous standard of care treatment. Patient-specific tumor protein p53 (TP53) assays were developed for 31 unique mutations identified in formalin-fixed paraffin-embedded tumor DNA from these patients.

Digital polymerase chain reaction (PCR) was performed using the Biomark microfluidic system. Total circulating cell-free DNA was measured as the TP53 total allele count (TP53TAC), the sum of estimated targets of mutated and wild-type copies of TP53 amplified by the assay primers. Serum CA-125 level was routinely monitored using a two-site sandwich immunoassay on a Siemens Centaur XP auto-analyzer (upper limit of normal ≤ 30 IU/ml).

The investigators found that the median TP53MAF prior to treatment in 51 relapsed treatment courses was 8% (interquartile range [IQR] 1.2%–22%) compared to 0.7% (IQR 0.3%–2.0%) for seven untreated newly diagnosed stage IIIC/IV patients. The ratio of TP53MAF to volume of disease was higher in relapsed patients than in untreated patients. In 49 treatment courses for relapsed disease, pre-treatment TP53MAF concentration, but not CA-125, was associated with time to progression (TTP). Specificity was improved when patients with recent drainage of ascites were excluded. Ascites drainage led to a reduction of TP53MAF concentration.

The authors concluded that ctDNA is correlated with volume of disease at the start of treatment in women with HGSOC and that a decrease of less than 60% in TP53MAF after one cycle of chemotherapy was associated with shorter TTP. These results provide evidence that ctDNA has the potential to be a highly specific early molecular response marker in HGSOC. James Brenton, MD, a medical oncologist and senior author of the study, said, “Though we’re at an early stage, the results are an exciting signal that levels of faulty DNA in the blood are related to the tumor size, and that changes in these levels could one day be a signpost for doctors and patients to decide if treatment is working for them.” The study was published on December 30, 2016, in the journal Public Library of Science Medicine.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.