Performance of Second Generation Cortisol Assay Evaluated

By LabMedica International staff writers
Posted on 21 Dec 2016
Untreated disorders of the adrenocortical system, such as Cushing’s or Addison’s disease, can be fatal, and accurate quantification of a patient’s cortisol levels is vital for diagnosis. More...
A straightforward diagnostic approach is of essential importance, and accurate quantification of cortisol levels plays a key role in the diagnosis of patients with suspected disease.

Cortisol levels are often measured from a patient’s serum or plasma, which reflects total cortisol, both free and bound. However, in patients with liver disease, and for those receiving estrogen treatments or with critical illness, total serum cortisol levels may be difficult to interpret because of the variation in binding proteins.

Laboratory scientists at the Hospital of the University of Munich (Munich, Germany) and their colleagues performed a technical evaluation of the Elecsys Cortisol II assay (Roche Diagnostics GmbH, Mannheim, Germany) between June and November 2014 at four European investigational sites: three in Germany (Munich, Heidelberg, and Leipzig) and one in Belgium (Ghent). All sites used cobas e 411 analyzers for the Cortisol II assay experiments and in addition to a cobas e 411 system, the Leipzig site utilized a cobas e 601 analyzer. The Cortisol II assay was also compared with in-house isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays.

The team reported that for the method comparison studies, the serum samples covered a measuring range of 1.7 to 1,735 nmol/L and the saliva samples from 1.5 to 209.5 nmol/L. For the 405 serum samples, the agreement between the Cortisol II assay and LC-MS/MS was high, and the mean bias for serum samples measured on the Cortisol II assay compared with LC-MS/MS was 14.55 nmol/L. The correlation coefficient for the relationship between the Cortisol II assays versus LC-MS/MS for 253 saliva samples was 0.993, and for these comparisons, the mean bias was 2.56 nmol/L.

The authors concluded that for the Cortisol II assay, they observed a degree of between-laboratory and between-production lot reproducibility and agreement with several assays of higher metrological order that they consider compatible with the diagnostic use of this assay. The Cortisol II assay will be beneficial to endocrinologists in assessing patients with adreno-cortisol disorders. The study was published on November 29, 2016, in the journal Clinical Chemistry and Laboratory Medicine.

Related Links:
Hospital of the University of Munich
Roche Diagnostics


New
Gold Member
Hematology Analyzer
Medonic M32B
Collection and Transport System
PurSafe Plus®
New
Anterior Nasal Specimen Collection Swabs
53-1195-TFS, 53-0100-TFS, 53-0101-TFS, 53-4582-TFS
New
Gold Member
Automatic Hematology Analyzer
DH-800 Series
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: New research points to protecting blood during radiation therapy (Photo courtesy of 123RF)

Pioneering Model Measures Radiation Exposure in Blood for Precise Cancer Treatments

Scientists have long focused on protecting organs near tumors during radiotherapy, but blood — a vital, circulating tissue — has largely been excluded from dose calculations. Each blood cell passing through... Read more

Immunology

view channel
Image: The VENTANA HER2 (4B5) test is now CE-IVDR approved (Photo courtesy of Roche)

Companion Diagnostic Test Identifies HER2-Ultralow Breast Cancer and Biliary Tract Cancer Patients

Breast cancer is the most common cancer in Europe, with more than 564,000 new cases and 145,000 deaths annually. Metastatic breast cancer is rising in younger populations and remains the leading cause... Read more

Pathology

view channel
Image: An adult fibrosarcoma case report has shown the importance of early diagnosis and targeted therapy (Photo courtesy of Sultana and Sailaja/Oncoscience)

Accurate Pathological Analysis Improves Treatment Outcomes for Adult Fibrosarcoma

Adult fibrosarcoma is a rare and highly aggressive malignancy that develops in connective tissue and often affects the limbs, trunk, or head and neck region. Diagnosis is complex because tumors can mimic... Read more

Technology

view channel
Image: Conceptual design of the CORAL capsule for microbial sampling in the small intestine (H. Mohammed et al., Device (2025). DOI: 10.1016/j.device.2025.100904)

Coral-Inspired Capsule Samples Hidden Bacteria from Small Intestine

The gut microbiome has been linked to conditions ranging from immune disorders to mental health, yet conventional stool tests often fail to capture bacterial populations in the small intestine.... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.