Multiple Coagulation Parameters Predict Postoperative Bleeding Volume in Cardiovascular Surgery

By LabMedica International staff writers
Posted on 02 Dec 2021
Print article
Image: The CP3000Automated Coagulation System measures various coagulation factors (Photo courtesy of Sekisui Medical Company)
Image: The CP3000Automated Coagulation System measures various coagulation factors (Photo courtesy of Sekisui Medical Company)
Coagulopathy and massive bleeding are severe complications of cardiovascular surgery, particularly occurring after procedures requiring prolonged cardiopulmonary bypass (CPB). During surgery massive transfusion of blood products may become necessary.

Reliable and predictive laboratory tests on coagulation function will help guide clinicians to appropriate transfusion and possibly decrease variability in transfusion practices. Appropriate coagulation parameters would help to predict bleeding after cardiovascular surgery and measuring multiple coagulation parameters may prove useful.

Medical Laboratorians at the Asahikawa Medical University Hospital (Asahikawa, Japan) and their colleagues in a prospectively study collected cohort of 48 patients undergoing cardiovascular surgery from November 2015 to March 2016. They examined the association between coagulation parameters and bleeding volume. The median age of the cohort was 69 years, 29 males and 19 females and all were ethnically Asian.

The team measured prothrombin time (PT) or activated partial thromboplastin time (APTT) and fibrinogen (Fib) with the Coapresta2000 automated analyzer (coagulation one-stage assay (Sekisui Medical Company, Tokyo, Japan). Activities of coagulation factor II (FII), FV, FVII, FVIII, FIX, FX, FXI and FXII were measured with Sekisui Medical Company’s Coapresta3000. α2 Plasmin inhibitor (α2PI, synthetic substrate assay), antithrombin (AT, synthetic substrate assay), thrombin-antithrombin complex (TAT, chemiluminescent enzyme immunoassay) and FXIII activity (synthetic substrate assay) were measured using the STACIA automated analyzer (LSI Medience Corporation, Tokyo, Japan).

The scientists reported that bleeding volume during surgery was 2,269 (174–10,607) mL. Number of transfusion units during surgery were packed red blood cells 12 (0–30) units, fresh frozen plasma 12 (0–44) units, platelets 20 (0–60) units and intraoperative autologous blood collection 669 (0–4,439) mL. Post-surgery activities of coagulation factors II (FII), FV, FVII, FVIII, FIX, FX, FXI and FXII were decreased. Values of fibrinogen, antithrombin, α2 plasmin inhibitor (α2PI) and FXIII were also decreased. Values of thrombin-antithrombin complex (TAT) were increased. Values of FII, FIX, FXI and α2PI before surgery were negatively correlated with bleeding volume. Level of FIX after surgery was negatively correlated with bleeding volume and level of TAT after surgery was positively correlated with bleeding volume.

The authors concluded that FII, FIX, FXI, FXIII and α2PI are associated with postoperative bleeding volume. Diluted coagulopathy, decrease in stabilized fibrin due to decrease in FXIII and hyperfibrinolysis due to decrease in α2PI may contribute to hemostatic defect. Thrombin burst due to operative stress as represented by increase in TAT values may also contribute to hemostatic defect. The study was published on October 9, 2021 in the Thrombosis Journal.

Related Links:
Asahikawa Medical University Hospital
Sekisui Medical Company
LSI Medience Corporation


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
HLX
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.