Multiple Coagulation Parameters Predict Postoperative Bleeding Volume in Cardiovascular Surgery

By LabMedica International staff writers
Posted on 02 Dec 2021
Coagulopathy and massive bleeding are severe complications of cardiovascular surgery, particularly occurring after procedures requiring prolonged cardiopulmonary bypass (CPB). More...
During surgery massive transfusion of blood products may become necessary.

Reliable and predictive laboratory tests on coagulation function will help guide clinicians to appropriate transfusion and possibly decrease variability in transfusion practices. Appropriate coagulation parameters would help to predict bleeding after cardiovascular surgery and measuring multiple coagulation parameters may prove useful.

Medical Laboratorians at the Asahikawa Medical University Hospital (Asahikawa, Japan) and their colleagues in a prospectively study collected cohort of 48 patients undergoing cardiovascular surgery from November 2015 to March 2016. They examined the association between coagulation parameters and bleeding volume. The median age of the cohort was 69 years, 29 males and 19 females and all were ethnically Asian.

The team measured prothrombin time (PT) or activated partial thromboplastin time (APTT) and fibrinogen (Fib) with the Coapresta2000 automated analyzer (coagulation one-stage assay (Sekisui Medical Company, Tokyo, Japan). Activities of coagulation factor II (FII), FV, FVII, FVIII, FIX, FX, FXI and FXII were measured with Sekisui Medical Company’s Coapresta3000. α2 Plasmin inhibitor (α2PI, synthetic substrate assay), antithrombin (AT, synthetic substrate assay), thrombin-antithrombin complex (TAT, chemiluminescent enzyme immunoassay) and FXIII activity (synthetic substrate assay) were measured using the STACIA automated analyzer (LSI Medience Corporation, Tokyo, Japan).

The scientists reported that bleeding volume during surgery was 2,269 (174–10,607) mL. Number of transfusion units during surgery were packed red blood cells 12 (0–30) units, fresh frozen plasma 12 (0–44) units, platelets 20 (0–60) units and intraoperative autologous blood collection 669 (0–4,439) mL. Post-surgery activities of coagulation factors II (FII), FV, FVII, FVIII, FIX, FX, FXI and FXII were decreased. Values of fibrinogen, antithrombin, α2 plasmin inhibitor (α2PI) and FXIII were also decreased. Values of thrombin-antithrombin complex (TAT) were increased. Values of FII, FIX, FXI and α2PI before surgery were negatively correlated with bleeding volume. Level of FIX after surgery was negatively correlated with bleeding volume and level of TAT after surgery was positively correlated with bleeding volume.

The authors concluded that FII, FIX, FXI, FXIII and α2PI are associated with postoperative bleeding volume. Diluted coagulopathy, decrease in stabilized fibrin due to decrease in FXIII and hyperfibrinolysis due to decrease in α2PI may contribute to hemostatic defect. Thrombin burst due to operative stress as represented by increase in TAT values may also contribute to hemostatic defect. The study was published on October 9, 2021 in the Thrombosis Journal.

Related Links:
Asahikawa Medical University Hospital
Sekisui Medical Company
LSI Medience Corporation



Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Fully-auto Specific Protein (Nephelometry) Analyzer
PA240
New
Silver Member
Vitamin D Assay
EZ Vitamin D Assay
New
Microbiology Laboratory Automation Solution
BD Kiestra™ ReadA+BarcodA
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image Credit: 123RF

UK Project Advances Blood-Based Dementia Testing Toward Routine Clinical Care

Dementia is the leading cause of death in the UK, accounting for almost one in eight deaths, with more than 72,000 people dying from dementia, including Alzheimer’s disease, in 2025. Despite this burden,... Read more

Microbiology

view channel
Image: Overview of a rapid diagnostic workflow for fungal bloodstream infections (Photo courtesy of Professor Hiroki Takahashi and IMO, Chiba University, Japan)

Genomic Workflow Identifies Fungal Pathogens Before Blood Cultures Turn Positive

Fungal bloodstream infections pose a major threat to hospitalized patients. Candida species cause most invasive fungal infections worldwide and are among the leading causes of hospital-acquired bloodstream... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image: TruVerus is designed to deliver a broad menu of routine blood tests from a small blood sample on a single, automated benchtop platform (Photo courtesy of Truvian Health)

Collaboration Advances Automated Benchtop Platform for Routine Blood Testing

Routine blood testing is central to clinical decision-making, but access can vary across laboratory and healthcare settings. Broader use of automated benchtop platforms may help integrate testing more... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.