Novel Non-Invasive Sampling Technique Diagnoses Cutaneous Leishmaniasis

By LabMedica International staff writers
Posted on 27 Jul 2017
Print article
Image: A) Determination of the lesion for disc sampling; B) Application of the tape strip disc on the lesion; C) Even pressure applied for 20 seconds with the plunger; and D) Detaching the disc and transferred into a sterile vial for DNA isolation (Photo courtesy of the Pasteur Institute of Iran).
Image: A) Determination of the lesion for disc sampling; B) Application of the tape strip disc on the lesion; C) Even pressure applied for 20 seconds with the plunger; and D) Detaching the disc and transferred into a sterile vial for DNA isolation (Photo courtesy of the Pasteur Institute of Iran).
The definitive diagnosis of cutaneous leishmaniasis requires parasitological detection and it is usually based on direct detection of amastigotes in smears from lesions by microscopy and by the culturing of promastigotes from infected tissues.

Although these techniques are highly specific, they require highly skilled health workers and have the inherent risks of all invasive procedures, such as pain and risk of bacterial and fungal super-infection. Therefore, it is essential to reduce discomfort, potential infection and scarring caused by invasive diagnostic approaches especially for children.

Scientists at the Pasteur Institute of Iran (Tehran, Iran) working with their colleagues at the Imperial College London (London, UK) recruited 119 patients suspected of suffering from cutaneous leishmaniasis with different clinical manifestations and samples were collected both from their lesions and from uninfected areas. In addition, 15 fungal-infected lesions and 54 areas of healthy skin were examined. There were 49 female and 70 males and the median age was 30 years (average 33 ± 20.3, range: 1 to 79 years old). The touch smear of dermal tissue of each patient was prepared by superficial incision on the margin of the lesion against a glass microscope slide, stained and examined.

For non-invasive skin sampling, one tape disc was placed on selected areas (infected and non-infected areas). In order to apply even pressure to the disc, a plunger was gently held on the selected areas and pressed for approximately 20 seconds. DNA was isolated from the strip and two polymerase chain reactions (PCR) assays were used in the study: First PCR was targeting the kDNA1 minicircle of Leishmania species and the second was for species identification (L. tropica and L. major).

The tape stripping technique used was child-friendly, causes virtually no pain, and is very practical for those lesions, which occur in sensitive areas such as the eyelids, lips and ears. Of the 119 confirmed CL patients enrolled in this study, 79 patients (66%) presented with acute CL (duration ranged from one up to 12 months), 32 (27%) with chronic CL (duration ranged from 30 up to 360 months). In total, 71 patients were infected with L. tropica (60%), 41 with L. major (34%) and seven were undetermined (6%). The highest diagnostic sensitivity of 100% was achieved with the tape strip disc technique. Of 31 suspected patients, only 16 were positive for culturing parasite from lesion biopsies (sensitivity 51%), which was significantly lower than tape strip disc sampling.

The authors concluded that the duration of sampling is short (less than one minute) and species identification by PCR is highly specific and sensitive. The sequential tape stripping sampling method is a sensitive, non-invasive and cost-effective alternative to traditional diagnostic assays and it is suitable for field studies as well as for use in health care centers. The study was published on July 13, 2017, in the journal Public Library of Science Neglected Tropical Diseases.

Related Links:
Pasteur Institute of Iran
Imperial College London

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
One Step HbA1c Measuring System
GREENCARE A1c
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.