Field Evaluation of Quantitative G6PD Diagnostics Reviewed

By LabMedica International staff writers
Posted on 27 Sep 2017
Glucose-6-phosphate dehydrogenase deficiency (G6PDd) is the most common enzymopathy with at least 400 million individuals affected worldwide. More...
More than 185 clinically relevant variants of G6PDd have been reported with a spectrum of associated enzyme deficiencies.

The presence of G6PDd in patients with Plasmodium vivax infection results in significant challenges to achieving radical cure. The 8-aminoquinolone compounds are the only class of anti-malarial drugs currently available to eliminate the dormant hypnozoites liver stages of P. vivax are and these cause hemolysis in G6PDd individuals.

Scientists at the Charles Darwin University (Sydney, Australia) and their colleagues reviewed the methods for the field evaluation of quantitative G6PD diagnostics. G6PD enzyme activity and its degradation is temperature dependent, hence whole EDTA blood should not be stored at room temperature. Freezing samples and maintaining a respective cold chain in a field setting is demanding and often impossible. Whole blood samples can be stored at 4–8 °C for later analysis; however the duration at which samples can be stored and reliably assayed at a later time point is unknown. Field evaluation is based on the comparison of paired samples, including one sample tested by the new assay at point of care and one sample tested by the gold-standard reference method, UV spectrophotometry in an established laboratory.

In one study the G6PD activity of paired samples collected from venous and capillary sampling were similar when measured by spectrophotometry, the medians were 7.51 and 7.61 U/gHb, respectively. Similarly, an evaluation of qualitative tests by fluorescent spot test (FST) and Carestart G6PD RDT showed 100% concordance between paired capillary and venous samples. ACCESS BIO has recently developed a Biosensor, a quantitative handheld device that measures G6PD activity based on the electrochemical properties of G6PD in blood samples.

The WST8/1-methoxy PMS test is a robust and cost effective alternative to estimate G6PD activity that can be performed on dried blood spots and whole blood samples. The WST8/1 test is based on the formation of an orange formazan dye generated by G6PD enzyme activity and facilitated by the 1-methoxy PMS as an electron carrier. The assay has been adapted for quantitative batch testing in a 96 well microplate and can be read by an enzyme-linked immunosorbent assay (ELISA) reader.

The authors concluded that their review presented a number of recommendations to facilitate standardized evaluation of quantitative G6PD activity test assays. Standardized evaluation studies are necessary to provide a comparable basis for subsequent pooled analyses. As novel quantitative G6PD diagnostics become available their potential to provide robust quantitative G6PD results suitable for field deployment needs to be assessed. The most recent generation of instruments contain an integrated temperature correction factor and hemoglobin measurement and G6PD activity is displayed normalized as U/gHb. The study was published on September 11, 2017, in the Malaria Journal.

Related Links:
Charles Darwin University



Gold Member
Automatic Hematology Analyzer
DH-800 Series
Portable Electronic Pipette
Mini 96
ESR Analyzer
TEST1 2.0
Pipette
Accumax Smart Series
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: New evidence shows viscoelastic testing can improve assessment of blood clotting during postpartum hemorrhage (Photo courtesy of 123RF)

Viscoelastic Testing Could Improve Treatment of Maternal Hemorrhage

Postpartum hemorrhage, severe bleeding after childbirth, remains one of the leading causes of maternal mortality worldwide, yet many of these deaths are preventable. Standard care can be hindered by delays... Read more

Immunology

view channel
Image: When assessing the same lung biopsy sample, research shows that only 18% of pathologists will agree on a TCMR diagnosis (Photo courtesy of Thermo Fisher)

Molecular Microscope Diagnostic System Assesses Lung Transplant Rejection

Lung transplant recipients face a significant risk of rejection and often require routine biopsies to monitor graft health, yet assessing the same biopsy sample can be highly inconsistent among pathologists.... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.