Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
INTEGRA BIOSCIENCES AG

A. Menarini Diagnostics S.r.l.

A. Menarini Diagnostics S.r.l. is fully committed to developing high tech diagnostics instruments and reagents to imp... read more Featured Products: More products

Download Mobile App




PD-L1 Expression in Circulating Tumor Cells Investigated for NSCLC

By LabMedica International staff writers
Posted on 07 Sep 2021
In non-small cell lung cancer (NSCLC), analysis of programmed cell death ligand 1 (PD-L1) expression in circulating tumor cells (CTCs) is a potential alternative to overcome the problems linked to the tumor biopsy spatiotemporal heterogeneity. More...
However, the prognostic significance of PD-L1-positive [PD-L1(+)] CTCs remains controversial.

Circulating tumor cells (CTCs) might better reflect the tumor heterogeneity than tissue biopsies because they arise from different tumor sites. Furthermore, as CTCs are collected using a minimally invasive method (blood sampling), they can be analyzed longitudinally as liquid biopsies, and might provide information on the different mechanisms of treatment resistance.

Oncologists and their colleague at the University Medical Centre of Montpellier (Montpellier, France) prospectively enrolled between June 2016 and June 2018 patients older than 18 years of age with histologically confirmed stage III or IV NSCLC. Blood sampling was performed at diagnosis, before the first treatment (n = 9), or later, at progression, before the next therapeutic line (n = 45).

Blood was drawn from the arm vein in specific 10 mL CellSave tubes (Menarini Silicon Biosystems, Bologna, Italy) for CTC detection. Blood samples were processed immediately with the CellSearch system (Huntington Valley, PA, USA). PD-L1 expression in CTCs was evaluated with the antihuman B7-H1/PD-L1 fluorescein isothiocyanate-conjugated antibody (R&D System, Minneapolis, MN, USA).

The investigators reported that they detected CTCs and PD-L1(+) CTCs in 43.4% and 9.4% of patients with NSCLC. PD-L1 expression concordance between tumor tissue and CTCs was low (54%). The presence of PD-L1(+) CTC correlated with the absence of gene alterations in tumor tissue and with poor prognosis-related biological variables (anemia, hyponatremia, increased lactate dehydrogenase). In univariate analysis, absence of gene alterations, number of metastatic sites, prior systemic therapies, and presence of CTCs and PD-L1(+) CTCs were associated with worse overall survival, whereas PD-L1 expression in tumor tissue was not. In multivariate analysis, squamous cell carcinoma histology, number of prior systemic treatments, and the presence of CTC were significantly associated with overall survival. Survival was worse in patients with PD-L1(+) CTCs than in patients with PD-L1-negative CTC or without any CTC.

The authors concluded that their data confirmed the feasibility of PD-L1 detection on CTCs in patients with advanced NSCLC, using the CellSearch technology, and suggest a negative prognostic impact of the PD-L1(+) CTC subpopulation. The weak concordance between PD-L1 expression on the tumor tissue and CTCs and the finding that only PD-L1 expression on CTCs predicted the clinical outcome suggest that tissue biopsy and CTCs are two complementary tools. The study was published on August 6, 2021 in the journal Clinical Chemistry.

Related Links:
University Medical Centre of Montpellier
Menarini Silicon Biosystems
CellSearch
R&D System



Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Nucleic Acid Extractor System
NEOS-96 XT
New
Nucleic Acid Purification Instrument
QIAsymphony Connect
New
Microbiology Laboratory Automation Solution
BD Kiestra™ ReadA+BarcodA
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image Credit: 123RF

Blood Biomarker May Track Bone Metastases in Medullary Thyroid Cancer

Medullary thyroid cancer (MTC) is a rare malignancy that often progresses silently, frequently going undetected until it reaches advanced stages. By the time it spreads to bone, it can produce unusual... Read more

Molecular Diagnostics

view channel
Image: In the Fetal Extracellular Vesicle Monitoring of Oxygenation (FEMOx) project several of the Wyss Institute’s Technology Platforms and faculty labs join forces. Leveraging and integrating multiple of the Wyss Institute’s technological innovations and advanced analytical capabilities they aim develop a test that can rapidly and accurately detect fetal oxygen deprivation by detecting specific miRNA signatures in extracellular vesicles (EVs) that circulate in maternal blood. (Iimage Credit: Wyss Institute at Harvard University)

Project to Develop Maternal Blood Test for Rapid Fetal Oxygen Deprivation Detection

Intrapartum fetal hypoxia remains difficult to assess with existing monitoring, leaving clinicians to make time-critical decisions with incomplete data. Limited detection and interpretation can contribute... Read more

Microbiology

view channel
Image: The current BDBV outbreak in the DRC underscores response challenges for rare, severe infections (Image Credit: 123RF)

Research Strengthens Bundibugyo Virus Outbreak Readiness with Faster Diagnostics

Bundibugyo virus (BDBV), a species of ebolavirus, causes severe hemorrhagic disease and can be difficult to diagnose rapidly during outbreaks. Recent regulatory changes have further complicated swift deployment... Read more

Technology

view channel
Image: The 5811 R retains the performance and versatility of its predecessor while adding a new design, a refreshed user interface, and updated sustainable cooling technology. (Photo courtesy of Eppendorf)

New Multipurpose Centrifuge Combines High Capacity with Sustainable Cooling

Laboratories often need centrifugation that accommodates multiple vessel formats while maintaining controlled temperatures to protect sensitive samples. Intuitive controls and repeatable operation can... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.