We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Rapid COVID Test Developed Solves Problems With LAMP Sensitivity

By LabMedica International staff writers
Posted on 14 Feb 2022

Researchers from the University of California, Santa Barbara have developed an isothermal amplification-based SARS-CoV-2 and influenza test that could retail for as little as $2 while addressing a key problem with loop-mediated isothermal amplification tests — false positive results. More...



Loop-mediated isothermal amplification (LAMP) diagnostics have gained attention for pathogen detection because they do not require sophisticated, expensive instrumentation or highly trained personnel for operation. Five principal tenets of point-of-care (POC) clinical diagnostics include speed, sensitivity, affordability, scalability, and accessibility, without a concomitant need of specialized and costly equipment.

Numerous methods for the detection of SARS-CoV-2 virus, including molecular, antigen, and serology tests, are currently in use. Although molecular methods such as polymerase chain reaction (PCR) are rapid and sensitive, they generally require access to specialized and costly laboratory instrumentation and highly trained personnel, and they are technologically complex for POC applications or resource-limited settings.

Molecular Biotechnologists at the University of California, Santa Barbara (Santa Barbara, CA, USA) and their colleagues enrolled two subgroups of participants (symptomatic and asymptomatic) at Santa Barbara Cottage Hospital (Santa Barbara, CA, USA). The symptomatic group consisted of 20 recruited patients who tested positive for SARS-CoV-2 with symptoms; 30 asymptomatic patients were recruited from the same community, through negative admission screening tests for SARS-CoV-2. Among the 50 eligible participants with no prior SARS-CoV-2 infection included in the study, 29 were men. The mean age was 57 years (range, 21 to 93 years).

The smartphone-based real-time loop-mediated isothermal amplification (smaRT-LAMP) was first optimized for analysis of human saliva samples spiked with either SARS-CoV-2 or influenza A or B virus. These results then were compared with those obtained by side-by-side analysis of spiked samples using the Centers for Disease Control and Prevention (CDC, Atlanta, GA, USA) criterion-standard reverse transcriptase–quantitative polymerase chain reaction (RT-qPCR) assay. Next, both assays were used to test for SARS-CoV-2 and influenza viruses present in blinded clinical saliva samples obtained from 50 hospitalized patients.

The investigators reported that SmaRT-LAMP exhibited 100% concordance (50/50 patient samples) with the CDC criterion-standard diagnostic for SARS-CoV-2 sensitivity (20/20 positive and 30/30 negative) and for quantitative detection of viral load. This platform also met the CDC criterion standard for detection of clinically similar influenza A and B viruses in 20 spiked saliva samples, and in saliva samples from hospitalized patients (50/50 negative). The smartphone-based LAMP assay was rapid (25 minutes), sensitive (1,000 copies/mL), low-cost (< USD 7/test), and scalable (96 samples/phone).

The authors concluded that the smartphone-based LAMP assay integrates reliable diagnostics with advantages of smartphone detection, offering an inexpensive diagnostic platform for SARS-CoV-2 and influenza A and B viruses that match the CDC RT-qPCR criterion standards. The study was published on January 28, 2022 in the journal JAMA Network Open.

Related Links:
University of California, Santa Barbara 
Santa Barbara Cottage Hospital
Centers for Disease Control and Prevention 


Gold Member
Automatic Hematology Analyzer
CF9600
Online QC Software
Acusera 24•7
New
Fully-auto Specific Protein (Nephelometry) Analyzer
PA240
Thyroid Test
Anti-Thyroid EIA Test
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: Capillary testing on the Atellica analyzers supports the most common laboratory testing needs (Photo courtesy of Siemens Healthineers)

Siemens Adds CE-Marked Capillary Claims for 24 Assays on Atellica Analyzers

Venous blood draws can be challenging in patients with difficult veins, needle phobia, or limited blood volume, and they can slow collection in busy services. Core laboratories also face pressure to expand... Read more

Immunology

view channel
Image: New findings show unique pathogen‑directed antibody patterns are already present years ahead of a formal diagnosis of inflammatory bowel disease (Image Credit: iStock)

Antibody Profiling Identifies Preclinical Inflammatory Bowel Disease Years Before Diagnosis

Inflammatory bowel disease often develops after a prolonged symptom-free period, complicating timely recognition and clinical intervention. Limited understanding of immune activity during this silent phase... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.