We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Sekisui Diagnostics

Download Mobile App




Machine Learning Cytology Tool Improves Cancer Cell Identification

By LabMedica International staff writers
Posted on 18 Sep 2026

Cytological screening remains central to early cancer detection, but its accuracy depends heavily on expert interpretation of stained cells. More...

Under conventional microscopy, malignant and reactive cells can appear nearly identical because some of their distinguishing features occur below the diffraction limit. Submicron changes in cytoskeletal structure, however, can alter how cells scatter light and provide an additional objective signal for classification. A new study now shows that machine learning analysis of light-scattering spectra can distinguish difficult-to-classify cancer cell types in cytology specimens.

Nara Institute of Science and Technology (NAIST; Nara, Japan) researchers developed a workflow that combines dark-field microscopy with machine learning to classify cells in routine cytology samples. The system captures white-light scattering from each cell across wavelengths of 420–720 nanometers, generating spectra that reflect nanometric structural features. These spectra are reduced using principal component analysis (PCA) and then classified with a support vector machine (SVM).

The team evaluated cytology specimens containing cancerous mesothelioma cells and morphologically similar reactive mesothelial cells. After training, the model differentiated these cell types with about 91% accuracy in patient-based validation. The approach also showed potential to distinguish gastric and urothelial cancer cells, as well as several lung and thoracic tumor cell types, although performance varied with tumor type and validation method.

Findings were published in Scientific Reports on August 3, 2026. Collaborators included Kindai University Faculty of Medicine, Nara Hospital, Hyogo Medical University Hospital, Hyogo Medical University School of Medicine, and Osaka Institute of Technology. The study is presented as proof of concept for augmenting conventional cytology with light-scattering information to support diagnostic decision-making. The team is optimizing optical settings and operating protocols and applying advanced machine learning methods to pursue further accuracy gains.

“The result implies that the light scattering spectrum, which contains information at the submicron scale, is very sensitive in detecting differences between cell types compared to visual inspection or image analysis,” said Yuka Tsuri, assistant professor at Nara Institute of Science and Technology.

“Integrating this spectroscopic system with a microscope could serve as a powerful aid for pathologists and potentially improve the accuracy of their diagnoses,” added Tsuri.

Related Links
Nara Institute of Science and Technology 


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
New
Gold Member
Serum Indices Control
Acusera Serum Indices Control
Electrolyte Analyzer
BKE-B
Automatic CLIA Analyzer
Shine i6000
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image Credit: iStock

Global TB Summit Connects Diagnostic Testing With Prevention and Clinical Care

Tuberculosis remains a major global infectious disease challenge despite declining deaths. In 2024, an estimated 10.7 million people worldwide developed the disease and nearly 1.2 million died from it.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.