We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Sekisui Diagnostics

Download Mobile App




Malaria Rapid Diagnostic Test Evaluated At Point-Of-Care

By LabMedica International staff writers
Posted on 22 Apr 2015
For over a decade, the development of malaria rapid diagnostic tests (RDTs) has enabled reliable biological diagnostic testing in all situations where previously only clinical diagnosis was available. More...
These RDTs are generally considered as point-of-care tests.

Most of the studies assessing the performance of malaria RDTs are conducted by trained scientific teams that are not representative of the classical end-users, who are typically unskilled in traditional laboratory techniques for diagnosing malaria. Consequently, only the basic performance of malaria RDTs is evaluated and information regarding their overall performance when they are used by the traditional end-users is lacking.

Scientists at the Institut Pasteur du Cambodge (Phnom Penh, Cambodia) tested three types of sample (negative, low positive, high positive) in replicates of four, corresponding to a panel of 20 aliquots, as followed: one negative sample, one low positive sample at 200 parasites of Plasmodium falciparum/μL, one low positive sample at 200 parasites of P. vivax/μL, one high positive sample at 2,000 parasites of P. falciparum/μL and one high positive sample at 2,000 parasites of P. vivax/μL. Twenty end-users with four different profiles in seven communes in Kampot Province (Cambodia) were selected.

The ready-to-use cassette device the VIKIA Malaria Ag Pf/Pan (IMACCESS/bioMérieux; Lyon, France) was the RDT used. This test is based on immunochromatographic technology for detecting P. falciparum and other species of Plasmodium (P. vivax, P. malariae, and P. ovale). The team performed a quality control assessment of the set of the 20 aliquots at three different times (at the start, middle and end of the study), to confirm the good quality of the aliquots distributed to the users and to verify that no degradation occurred during transport or storage that could affect the expected results.

All results obtained by the end-users were consistent with the expected results, except for the low positive (200 parasites/μL) P. vivax aliquot (35% of concordant results). No significant difference was observed between the different end-users. End-user interviews evaluating ease-of-use and ease-of-reading of the VIKIA Malaria Ag Pf/Pan kit recorded 159 positive answers and only one negative answer. Out of 20 end-users, only one considered the test was not easy to perform with the support of the quick guide.

The authors concluded that the performance of the VIKIA Malaria AgPf/Pan rapid test performed by traditional end-users in field conditions is similar to those obtained by a trained scientific team, and that VIKIA Malaria AgPf/Pan can be considered as a point-of-care test. In addition, the protocol designed for this study, using well-characterized and calibrated blood samples could be used systematically in parallel to conventional evaluation studies to determine the performance of malaria RDTs in field conditions. The study was published on March 14, 2015, in the Malaria Journal.

Related Links:

Institut Pasteur du Cambodge 
IMACCESS/bioMérieux 



Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
βeta-Hydroxybutyrate Reagent
β-Hydroxybutyrate LiquiColor®
Gold Member
Blood-Based Protein Biomarker Solution for Alzheimer's Disease
BG-DTi2000.
Gold Member
Neonatal Heel Incision Device
Tenderfoot
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The approach uses in-house pathology tests and streamlined access to specialists to shorten the diagnostic pathway for children with immune conditions. (Image Credit: iStock)

Streamlined Genetic Testing Speeds Pediatric Immune Disorder Diagnosis

Children with genetic immune conditions can develop life-threatening illness, unusual infections, or autoimmune problems before the underlying cause is identified. More than 500 of these rare disorders... Read more

Immunology

view channel
Image: Acute myeloid leukemia is the first of several disease areas the collaborators plan to pursue together as part of efforts to advance precision diagnostics (Image Credit: Adobe Stock)

Immune Profiling Initiative Aims to Improve Bone Marrow Analysis in Leukemia

Acute myeloid leukemia (AML) is an aggressive blood cancer in which assessing disease burden after therapy can help guide clinical evaluation. Patients with measurable residual disease (MRD) after treatment... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image: The acquisition of Reveal Genomics would expand Hologic’s oncology diagnostics portfolio to support treatment decisions for more women with breast cancer.

Hologic to Broaden Breast Cancer Testing Portfolio Through Reveal Genomics Acquisition

Hologic (Marlborough, MA, USA) has signed a definitive agreement to acquire Reveal Genomics (Barcelona, Spain), a precision oncology company developing genomic diagnostic tests to help personalize cancer treatment.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.