Staining Methods for Malarial Blood Films Compared

By LabMedica International staff writers
Posted on 11 Jan 2015
Early parasitological diagnosis of malaria is the cornerstone of malaria treatment and control and although rapid diagnostic tests for malaria are increasingly used, microscopy remains the reference standard for malaria diagnosis. More...


In malaria-endemic regions, thin and thick smear preparation are used to diagnose malaria, but examination of the blood elements can also reveal other causes of fever including leukemia, or clues for viral infection or bacterial sepsis depending on the staining technique used.

Scientists at the Mahidol University (Bangkok, Thailand) working with an international team in India examined peripheral blood slides from 1,180 fever cases admitted to a local hospital from August to December 2012. A sample of 10 µL ethylenediaminetetraacetic acid (EDTA) treated blood was used for the simultaneous preparation of two thin and thick smear slides, one stained according to Giemsa and the other according to Leishman method.

After fixation the blood slides were stained with either Giemsa stain (Qualigen; Mumbai, India) or Leishman stain (S D Fine-Chem Ltd.; Mumbai, India). In both Giemsa- and Leishman-stained slides, the thick smear was used for diagnosis and quantitative assessment, whereas the thin smear for species identification. Parasitemia in all malaria positive cases was quantified per 200 white blood cells (WBC) independently by two microscopists.

In the blood films from the 1,180 fever patients that were compared according to staining method, 111 were identified as parasitemic using Giemsa and 110 with Leishman staining. There were 92 with Plasmodium falciparum, 2 with P. vivax, and 17 with co-infections of both of these parasites. A total of 276 patients showed other abnormalities including shift to the left with toxic granulation of neutrophils, atypical lymphocytes, suggestive of infectious mononucleosis, and a single case of acute lymphoblastic leukemia (ALL). The difference in parasitemia between methods increased with increased parasite density.

The authors concluded that the Leishman's staining method for thin and thick smears is a good alternative to Giemsa's stain for identifying Plasmodium parasites, however the Leishman method was superior for visualization of red and white blood cell morphology. The time taken for staining was shorter with the Leishman method, which can be an important advantage in countries such as India where diagnostic laboratories are sometimes understaffed. The study was published on December 30, 2014, in the Malaria Journal.

Related Links:

Mahidol University
Qualigen 
S D Fine-Chem Ltd.



Gold Member
H-FABP Assay
Heart-Type Fatty Acid-Binding Protein Assay
Online QC Software
Acusera 24•7
Chromogenic Culture System
InTray™ COLOREX™ ECC
All-in-One Molecular System
AIO M160
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image:Schematic illustration of plasmonic microarray–based KRAS mutation detection from colorectal cancer patients. (Lee, J.Y., Mun, C.W., Kim, E.R. et al. npj Precision Oncology, 2026. https://doi.org/10.1038/s41698-026-01452-8)

Blood and Urine Liquid Biopsy Detects Early Colorectal Cancer Mutations

Early-stage colorectal cancer is difficult to assess noninvasively because tumor-derived mutations occur at extremely low levels in blood and urine, straining the sensitivity, cost, and turnaround time... Read more

Hematology

view channel
Image Credit: Shutterstock

New Biomarkers Predict Resistance to Targeted Therapy in Rare Blood Cancer

Blastic plasmacytoid dendritic cell neoplasm (BPDCN) is a rare and aggressive leukemia with limited treatment options and a poor prognosis. Although tagraxofusp is the first approved targeted therapy for... Read more

Immunology

view channel
Image:Proteomic tear-fluid analysis revealed abnormal patterns in proteins that regulate nerves and T cells in individuals with eye problems (Image Credit: Adobe Stock)

Diagnostic Models Detect Hidden Eye Abnormalities After Mild COVID-19

Persistent ocular symptoms after COVID-19 can severely affect reading, work, and daily tasks, yet standard eye exams often reveal no clear abnormalities. Patients experiencing photophobia, eye pain, and... Read more

Industry

view channel
Photo courtesy of Natera

Natera’s Signatera Earns IVDR Certification for Solid Tumor MRD Testing

Natera’s Signatera has received certification as a Class C device under the European Union’s In Vitro Diagnostic Regulation (IVDR), becoming the first personalized MRD test for solid tumors to achieve... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.