Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us

Download Mobile App




Urinary Schistosomiasis Diagnosed by On-Chip Computer Imaging

By LabMedica International staff writers
Posted on 22 Jan 2014
The universal diagnostic method for detection of most globally important parasitic infections is by microscopy as it is relatively easy to perform at low cost.

However, the quality control for microscopy is hard to maintain and misdiagnosis is common, which affects both estimates of parasite burdens and patient care.

Scientists at the Karolinska Institutet (Stockholm, Sweden) and their Finnish colleagues used novel techniques for high-resolution imaging and image transfer over data networks to offer solutions to these problems through provision of education, quality assurance, and diagnostics. More...
They studied the basic technique of imaging an object directly on the surface of an image sensor chip of a webcam or a mobile phone camera.

The studies were performed on urine sediment obtained by pooling urines from individuals shown to excrete Schistosoma haematobium eggs. For on-chip trials, aliquots of the sediment were diluted in saline to give a concentration of about 250 eggs per mL. For part of the samples they used a microscope (Leica; Wetzlar, Germany) equipped with an AxioCam digital camera (Carl Zeiss; Oberkochen, Germany). Imaging software on a desktop computer was used for image capture.

On-chip imaging was performed essentially by placing the specimen in contact with an image sensor, which was then illuminated to produce a shadow of objects present in the specimen. The Complementary Metal Oxide Semiconductor sensor chip of an imaging device was made available for imaging tests by removing the optics. The main results were obtained with the exposed sensor of a low cost webcam (Creative Technology Ltd.; Singapore).

The results of the study showed that an inexpensive webcam stripped off its optics to allow direct application of the test sample on the exposed surface of the sensor, yields images of S. haematobium eggs, which can be identified visually. Using a highly specific image pattern-recognition algorithm, four out of five eggs observed visually could be identified. On-chip imaging investigations performed using stool samples containing various helminth eggs showed that eggs from helminths of different species could be distinguished from each other. The system can be exploited for constructing simple imaging devices for low-cost diagnostics of urogenital schistosomiasis and other neglected tropical infectious diseases.

The authors concluded that a decisive advantage of a minimicroscope such as the one they describe might prove to have the potential of providing diagnostic support by computer vision at a distance. Furthermore, their results suggest that diagnostics based image analysis has a potential to compete with laborious conventional microscopy by providing automated motion recognition for the detection of live nematode larvae. The study was published on December 5, 2013, in the journal Public Library of Science Neglected Tropical Diseases.

Related Links:

Karolinska Institutet
Leica
Carl Zeiss



New
Gold Member
Hematology Analyzer
Medonic M32B
POC Helicobacter Pylori Test Kit
Hepy Urease Test
New
Sperm Quality Analyis Kit
QwikCheck Beads Precision and Linearity Kit
New
Gold Member
Hematology System
Medonic M16C
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: New research points to protecting blood during radiation therapy (Photo courtesy of 123RF)

Pioneering Model Measures Radiation Exposure in Blood for Precise Cancer Treatments

Scientists have long focused on protecting organs near tumors during radiotherapy, but blood — a vital, circulating tissue — has largely been excluded from dose calculations. Each blood cell passing through... Read more

Immunology

view channel
Image: The test could streamline clinical decision-making by identifying ideal candidates for immunotherapy upfront (Xiao, Y. et al. Cancer Biology & Medicine July 2025, 20250038)

Blood Test Predicts Immunotherapy Efficacy in Triple-Negative Breast Cancer

Triple-negative breast cancer (TNBC) is an aggressive subtype lacking targeted therapies, making immunotherapy a promising yet unpredictable option. Current biomarkers such as PD-L1 expression or tumor... Read more

Pathology

view channel
image: Researchers Marco Gustav (right) and MD Nic G. Reitsam (left) discuss the study data (Photo courtesy of Anja Stübner/EKFZ)

AI Model Simultaneously Detects Multiple Genetic Colorectal Cancer Markers in Tissue Samples

Colorectal cancer is a complex disease influenced by multiple genetic alterations. Traditionally, studies and diagnostic tools have focused on predicting only one mutation at a time, overlooking the interplay... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.