We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Sekisui Diagnostics

Download Mobile App




New One-Step Syphilis Test Could Enable Earlier Detection and Faster Treatment

By LabMedica International staff writers
Posted on 19 Oct 2026

Syphilis can be difficult to diagnose because its symptoms may resemble other diseases and appear and disappear without treatment. More...

Undetected infection can continue causing harm, spread to partners and pass to babies during pregnancy. In 2024, nearly 4,000 babies in the U.S. were born with syphilis. To support earlier detection, researchers have developed a rapid testing approach designed to identify low levels of antibodies associated with the infection.

Researchers at the Pennsylvania State University (Penn State; University Park, PA, USA) have developed a new pilot rapid syphilis testing device that integrates the treponemal and non-treponemal blood test sequence into one format. The test is designed to detect antibodies against Treponema pallidum and separate antibodies associated with disease-related cellular damage. This approach is intended to reproduce established diagnostic information in a faster, potentially point-of-care format.

The device uses multilayer gold-silver-gold nanoparticles instead of conventional gold nanoparticles to generate a stronger visible test line. The silver layer provides stronger optical properties, while the gold layers help preserve particle stability. Before embedding the particles in a lateral flow reporter, the researchers found that six times fewer multilayer particles were needed to form a visible mark than gold alone, and the particles remained visible with three times fewer sample target molecules.

The team evaluated the nanoparticles using 36 clinical specimens spanning a range of antibody concentrations from the U.S. Centers for Disease Control and Prevention and Boca Biolistics. In those experiments, line intensities increased 19% to 46% compared with conventional gold nanoparticles. The largest gains occurred in tests detecting antibodies at the lowest concentrations.

The study was published in ACS Sensors and involved Penn State, Penn State College of Medicine, and Louisiana State University. The researchers stated that two rapid syphilis tests have been approved by the U.S. Food and Drug Administration in recent years, but these detect only treponemal antibodies. They also stated that no single-step confirmatory syphilis test is approved for U.S. use, and that a European test does not detect antibodies in the low-titer range.

The team has applied for a patent for the device and is exploring industry partnerships as it moves toward larger validation studies, further prototype development, and regulatory submission. The researchers said the approach could shift testing from a multistep laboratory process toward diagnosis and treatment during one clinical visit.

“The low-titer range, meaning the range with the lowest concentration of antibodies, is particularly challenging for detecting syphilis. This range is also clinically important, occurring during early infection, later stages of syphilis or after treatment when antibody levels are declining to make sure treatment worked,” said Dipanjan Pan, Penn State’s Dorothy Foehr Huck & J. Lloyd Huck Chair Professor in Nanomedicine.

“We could potentially move syphilis testing from a multistep laboratory process toward a model of testing, diagnosing and treating in a single clinical visit,” concluded Pan.

Related Links
Penn State


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
βeta-Hydroxybutyrate Reagent
β-Hydroxybutyrate LiquiColor®
Microbiology Laboratory Automation Solution
BD Kiestra™ ReadA+BarcodA
Gold Member
Neonatal Heel Incision Device
Tenderfoot
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: The test combines RNA signals from the tumor-immune microenvironment to predict treatment response, rather than relying on a single marker such as PD-L1 expression.(Image Credit: Adobe Stock)

RNA-Based Test Predicts Immunotherapy Response in Non-Small Cell Lung Cancer

Non-small cell lung cancer (NSCLC) represents the largest U.S. patient population eligible for immune checkpoint inhibitor therapy. Treatment selection often relies on PD-L1 expression, but a single protein... Read more

Immunology

view channel
Image Credit: Adobe Stock

Immune Profiling Identifies Early Maternal Autoantibodies Linked to Preterm Birth Risk

A typical pregnancy lasts about 40 weeks, but labor begins prematurely in roughly one in 10 pregnancies. Preterm birth is the leading cause of newborn death worldwide, yet its underlying causes and which... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image Credit: iStock

Global TB Summit Connects Diagnostic Testing With Prevention and Clinical Care

Tuberculosis remains a major global infectious disease challenge despite declining deaths. In 2024, an estimated 10.7 million people worldwide developed the disease and nearly 1.2 million died from it.... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.