Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
LGC Clinical Diagnostics

PERKIN ELMER CORPORATION

PerkinElmer provides detection technologies to detect and identify diseases, imaging technologies to help visualize s... read more Featured Products: More products

Download Mobile App




Simple Colorimetric Assay Determines Human Mercaptalbumin Concentration

By LabMedica International staff writers
Posted on 30 Jun 2022

Human serum albumin (HAS) can take on two forms, mercaptalbumin (HMA) or non-mercaptalbumin (HNA), depending on the redox status of its Cys34. More...

The ratio of HMA and HNA is considered to be a novel biomarker of oxidative stress.

The majority of studies on the redox state of HSA utilize high performance liquid chromatography (HPLC). Several recent studies have also employed mass spectrometry, which yields a higher resolution, thus allowing for finer distinctions between molecular structures. A handful of studies have explored alternative approaches using simple dye-based assays.

Clinical Laboratorians at The University of Tokyo Hospital (Tokyo, Japan) collaborated with colleagues at Nitto Boseki Co. Ltd., (Kawasaki, Japan) measured the concentrations of HMA in serum samples from 36 healthy subjects based on absorption changes of Michler's Hydrol. Michler's Hydrol (4,4′-Bis(dimethylamino)benzhydrol) is a blue dye with a maximum absorption at 612 nm, and its absorption decreases when it reacts with a thiol group.

After processing the samples, the solution was incubated further at room temperature for 20 minutes and absorbance at 612 nm (A612) was measured by a 96-well plate Nivo 3F microplate reader (PerkinElmer, Waltham, MA, USA). To evaluate the performance of the assays, the correlation was determined by a linear regression between the HMA concentrations obtained by Michler's Hydrol assay and corresponding reference concentrations obtained by HPLC and Bromocresol purple (BCP) assays.

The scientists reported that HMA concentrations obtained by Michler's Hydrol assay were highly correlated (r2 = 0.97) with reference values obtained by HPLC (HMA %) and BCP assay (total albumin). The HNA% obtained by Michler's Hydrol and BCP assays combined also gave a good correlation (r2 = 0.96) and a small deviation (average 2.4%) with respect to HPLC as a reference method. The use of the HMA/HNA ratio, which is a function of oxidation of Cys34, is considered a potential biomarker to assess the severity of chronic diseases for which oxidative stress is a significant etiological manifestation.

The authors concluded that the concentrations of HMA in human serum can be measured by Michler's Hydrol assay, which is based on an approximation of HMA concentrations with Michler's Hydrol's colorimetric changes mainly due to thiols. The assay accuracy was significantly improved by pre-incubation of a subset of the samples with an alkylating agent (iodoacetamide) and subtracting their absorption from the absorption of corresponding samples without alkylation. Proportions of HMA and HNA were also obtained by combining Michler's Hydrol assay and the BCP assay (for total albumin concentration). The results correlated well with HPLC, which has been established as a standard method for HMA/HNA measurement. The study was published on June 8, 2022 in the journal Practical Laboratory Medicine.

Related Links:
The University of Tokyo Hospital
Nitto Boseki Co. Ltd
PerkinElmer

 


New
Gold Member
Quality Control Material
iPLEX Pro Exome QC Panel
3-Part Differential Hematology Analyzer
Swelab Alfa Plus Sampler
New
Modular Hemostasis Automation Solution
CN Track
New
Drug Test Kit
DrugCheck 3000
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Hematology

view channel
Image: CitoCBC is the world first cartridge-based CBC to be granted CLIA Waived status by FDA (Photo courtesy of CytoChip)

Disposable Cartridge-Based Test Delivers Rapid and Accurate CBC Results

Complete Blood Count (CBC) is one of the most commonly ordered lab tests, crucial for diagnosing diseases, monitoring therapies, and conducting routine health screenings. However, more than 90% of physician... Read more

Immunology

view channel
Image: A simple blood test could replace surgical biopsies for early detecion of heart transplant rejection (Photo courtesy of Shutterstock)

Blood Test Detects Organ Rejection in Heart Transplant Patients

Following a heart transplant, patients are required to undergo surgical biopsies so that physicians can assess the possibility of organ rejection. Rejection happens when the recipient’s immune system identifies... Read more

Pathology

view channel
These images illustrate how precision oncology Organ Chips recapitulate individual patients’ responses to chemotherapy (Photo courtesy of Wyss Institute at Harvard University)

Cancer Chip Accurately Predicts Patient-Specific Chemotherapy Response

Esophageal adenocarcinoma (EAC), one of the two primary types of esophageal cancer, ranks as the sixth leading cause of cancer-related deaths worldwide and currently lacks effective targeted therapies.... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.