We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
BIO-RAD LABORATORIES

Download Mobile App




Recombinant Antigens Assessed for Serological Diagnosis of Syphilis

By LabMedica International staff writers
Posted on 09 Aug 2022
Print article
Image: Photomicrograph of Treponema pallidum bacterial spirochetes, which exhibited their characteristic corkscrew shape using the dark field visualization technique (Photo courtesy of Louisa Lu, MD)
Image: Photomicrograph of Treponema pallidum bacterial spirochetes, which exhibited their characteristic corkscrew shape using the dark field visualization technique (Photo courtesy of Louisa Lu, MD)

Syphilis is a chronic multisystemic disease caused by infection with the spirochete Treponema pallidum and acquired usually via sexual exposure or via vertical mother–fetus transmission or by blood transfusions. An estimated 18 million cases worldwide and 5.6 million new cases occur annually.

Currently, diagnosis remains primarily dependent on serologic tests due to the inability to culture T. pallidum in vitro. The serological tests for the diagnosis of syphilis are divided into non-treponemal tests and treponemal tests. Some of these tests are expensive, labor-intensive, time-consuming, highly operator-dependent, and not suitable for high-volume screening.

Biomedical Scientists at the Hengyang Medical School (Hengyang, China) and their colleagues collected human serum samples from patients with clinically diagnosed primary (n = 21), secondary (n = 78), latent (n = 228), and tertiary (n = 13) syphilis, healthy controls (n = 60), and hepatitis B (n = 56), tuberculosis (n = 20), rheumatoid arthritis (RA) (n = 40), systemic lupus erythematosus (SLE) (n = 40), between March 2019 and August 2020.

Two recombinant T. pallidum proteins Tp0100 and Tp1016 were expressed, purified, and identified by Western Blotting. A total of 600 clinical serum samples were tested with the Tp0100-based ELISA, the Tp1016-based ELISA, and the commercial LICA Syphilis TP kit (CHIVD Chemclin Diagnostics Corporation, Beijing, China). The sensitivities were determined by testing 340 samples from individuals with clinically diagnosed primary, secondary, latent, and tertiary syphilis. The specificities were determined by screening 260 samples from healthy controls and individuals with potentially cross-reactive infections. The team also performed indirect IgG enzyme-linked immunosorbent assays and light-initiated chemiluminescent assays (LICA).

The scientists used clinical syphilis diagnosis as the gold standard, Tp0100 exhibited an overall sensitivity of 95.6% and specificity of 98.1% for testing IgG antibody while Tp1016 demonstrated only an overall sensitivity of 75.0% and specificity of 79.6%. In contrast, the LICA Syphilis TP test revealed an overall sensitivity of 97.6% and specificity of 96.2%. In addition, the overall percent agreement and corresponding κ values were 96.7% (95% CI 95.6%–97.8%) and 0.93% for the Tp0100-based ELISA, 77.0% (95% CI 74.3%–79.7%) and 0.54% for the Tp1016-based ELISA, and 97.0% (95% CI 96.0%–98.0%) and 0.94 for the LICA Syphilis TP test, respectively.

The authors concluded that the recombinant T. pallidum protein Tp0100 showed promise as a novel diagnostic antigen in the serological tests for syphilis. The study was published on July 31 2022 in the Journal of Clinical Laboratory Analysis.

Related Links:
Hengyang Medical School 
CHIVD Chemclin Diagnostics Corporation 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.