Multiplex Assay Detects Pathogens in NF Patients

By LabMedica International staff writers
Posted on 23 Apr 2019
Necrotizing fasciitis (NF) is a life-threatening deep soft tissue infection characterized by rapidly progressive necrosis of the fascia and the adjacent soft tissues. More...
NF of the extremities is associated with high mortality rates, and immediate surgical intervention is required upon detection of NF infections.

Early diagnosis and bacterial identification are essential for adequate surgical treatment and appropriate antibiotic administration in patients with NF. The clinical signs and symptoms of NF caused by Gram-positive and Gram-negative microorganisms are characteristically indistinguishable at the time of presentation. Moreover, it takes 3 to 4 days to obtain the results of microbiological analysis and antimicrobial sensitivity testing of the specimens.

Scientists from Chang Gung Memorial Hospital (Taoyuan City, Taiwan) collected samples from 99 patients with surgically confirmed NF of the extremities who were hospitalized consecutively between June 2015 and November 2017. Two sets of blood and tissue samples were collected from all patients; one set was sent to a microbiology laboratory for bacterial identification and the other set was sent to an immunohistochemistry laboratory for polymerase chain reaction (PCR) amplification.

The culture specimens were obtained from the infected wounds or the blood, and were identified by microbiological evaluation. Genomic bacterial DNA extraction was performed and 16S rDNA universal PCR was performed for each sample to validate the results of the multiplex PCR assay. Total genomic DNA was purified using a Geneaid Bacteria Genomic DNA Kit and amplified. PCR amplicons were analyzed by electrophoresis in 2% agarose gel.

The multiplex PCR results for the blood samples showed negative findings. The multiplex PCR results for the tissue specimens showed 28 positive findings. Fourteen (87.5%) of the 16 Vibrio vulnificus culture-positive tissue specimens, six (75%) of the eight Aeromonas hydrophila culture-positive tissue specimens, and four (100%) of the four methicillin-resistant Staphylococcus aureus (MRSA) culture-positive tissue specimens were positive by PCR. Similarly, two (100%) of the group A Streptococcus and two (100%) of the group B Streptococcus were PCR-positive.

The authors concluded that the accuracy rate of the multiplex PCR presenting positive results in these culture-positive tissue samples was 87.5% (28/32). This suggests that multiplex PCR of tissue specimens may be a useful and rapid diagnostic tool for the detection of these lethal microorganisms in patients with NF. The study was published in the April 2019 issue of the International Journal of Infectious Diseases.

Related Links:
Chang Gung Memorial Hospital


Gold Member
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Sample Transportation System
Tempus1800 Necto
Laboratory Software
ArtelWare
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: LiDia-SEQ aims to deliver near-patient NGS testing capabilities to hospitals, labs and clinics (Photo courtesy of DNAe)

World's First NGS-Based Diagnostic Platform Fully Automates Sample-To-Result Process Within Single Device

Rapid point-of-need diagnostics are of critical need, especially in the areas of infectious disease and cancer testing and monitoring. Now, a direct-from-specimen platform that performs genomic analysis... Read more

Hematology

view channel
Image: Residual leukemia cells may predict long-term survival in acute myeloid leukemia (Photo courtesy of Shutterstock)

MRD Tests Could Predict Survival in Leukemia Patients

Acute myeloid leukemia is an aggressive blood cancer that disrupts normal blood cell production and often relapses even after intensive treatment. Clinicians currently lack early, reliable markers to predict... Read more

Pathology

view channel
Image: The AI tool advances precision diagnostics by linking genetic mutations directly to disease types (Photo courtesy of Shutterstock)

AI Tool Simultaneously Identifies Genetic Mutations and Disease Type

Interpreting genetic test results remains a major challenge in modern medicine, particularly for rare and complex diseases. While existing tools can indicate whether a genetic mutation is harmful, they... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.