Methods Compared for Chagas Disease Diagnosis

By LabMedica International staff writers
Posted on 08 Aug 2017
Chagas Disease (CD) is a chronic infectious disease caused by the protozoan flagellate Trypanosoma cruzi. More...
In endemic countries, CD is transmitted mainly through the contact with feces of different triatomine bugs. Due to increased migration, CD has become an international health problem.

CD presents itself in two phases: whereas the acute phase is dominated by unspecific or no symptoms at all, in the chronic phase cardiac and/or gastrointestinal symptoms can occur after a long asymptomatic interval. Reliable diagnosis of chronically infected people is crucial for prevention of non-vectorial transmission as well as treatment.

European scientists led by those at the Medical Center of the University of Munich (Germany) tested samples consisting of 50 human EDTA blood samples that were previously tested positive by enzyme-linked immunosorbent assay (ELISA), immunofluorescence antibody test (IFAT) and polymerase chain reaction (PCR) for T. cruzi in the Instituto de Salud Carlos III, (Madrid, Spain) during 2010–2013. This study compared four distinct PCR methods for detection of T. cruzi DNA for the use in well-equipped routine diagnostic laboratories.

The team chose two conventional and two real-time PCR methods for closer evaluation. DNA was extracted of T. cruzi-positive and negative patients' blood samples and cultured T. cruzi, T. rangeli as well as Leishmania spp. One conventional and two real-time PCR methods targeting a repetitive satellite-DNA sequence as well as one conventional PCR method targeting the variable region of the kDNA minicircle were compared for sensitivity, intra- and interassay precision, limit of detection, specificity and cross-reactivity. For two methods the Professional Standard thermal cycler was operated, and for the other methods, the CFX C1000 Real-Time thermal cycler was used.

The team found that out of the 50 previously positive tested samples by serology and PCR, 44 samples were detected by all four methods. One method detected T. cruzi in all 50 samples. Potentially cross reactive agents (L. tropica, L. donovani, L. infantum, L. braziliensis, L. major, T. rangeli and T. brucei) showed similar results in all four methods. The costs of consumables are significantly cheaper for conventional methods than for real-time methods. The price of the conventional methods was below EUR 1/test, while it is around EUR two and eight per test for the relay time methods. The study was published in the July 2017 edition of the journal Diagnostic Microbiology and Infectious Disease.

Related Links:
Medical Center of the University of Munich
Instituto de Salud Carlos III


Gold Member
Blood Gas Analyzer
Stat Profile pHOx
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Automated MALDI-TOF MS System
EXS 3000
Sperm Quality Analyis Kit
QwikCheck Beads Precision and Linearity Kit
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: LiDia-SEQ aims to deliver near-patient NGS testing capabilities to hospitals, labs and clinics (Photo courtesy of DNAe)

World's First NGS-Based Diagnostic Platform Fully Automates Sample-To-Result Process Within Single Device

Rapid point-of-need diagnostics are of critical need, especially in the areas of infectious disease and cancer testing and monitoring. Now, a direct-from-specimen platform that performs genomic analysis... Read more

Hematology

view channel
Image: Residual leukemia cells may predict long-term survival in acute myeloid leukemia (Photo courtesy of Shutterstock)

MRD Tests Could Predict Survival in Leukemia Patients

Acute myeloid leukemia is an aggressive blood cancer that disrupts normal blood cell production and often relapses even after intensive treatment. Clinicians currently lack early, reliable markers to predict... Read more

Pathology

view channel
Image: The AI tool advances precision diagnostics by linking genetic mutations directly to disease types (Photo courtesy of Shutterstock)

AI Tool Simultaneously Identifies Genetic Mutations and Disease Type

Interpreting genetic test results remains a major challenge in modern medicine, particularly for rare and complex diseases. While existing tools can indicate whether a genetic mutation is harmful, they... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.