Rapid Ebola Virus Detection Assay Evaluated

By LabMedica International staff writers
Posted on 17 Nov 2015
Ebolavirus (EBOV) infection is mainly diagnosed by various in-house and commercial real-time reverse transcriptase polymerase chain reaction (RT-PCR) assays used in up to 38 laboratories implemented at or close to Ebola treatment centers (ETC) in West Africa.

Transmission of Ebolavirus disease (EVD) occurs almost exclusively from human to human by direct contact with body fluids of symptomatic cases. More...
Consequently, the control strategy for EVD epidemics relies on early identification of EBOV-infected patients and corpses for, respectively, isolation and safe burials.

An international team of scientists led by those at the Institut Pasteur de Dakar (Dakar, Senegal) evaluated a new nucleic acid extraction kit on sera and swabs in combination with an improved diagnostic reverse transcription recombinase polymerase amplification assay for the detection of Ebolavirus (EBOV-RT-RPA) that was compared in parallel to other methods. Serum samples from acute cases and cheek and tongue swabs from deceased were collected. In addition, following an upsurge of EVD cases connected to funeral rites, oral swabs from all deceased were tested at the morgue.

The extraction kit tested was the SpeedXtract Nucleic Acid Kit (SE), (Qiagen; Hilden, Germany). The W-PCR was performed on the SmartCycler (Cepheid; Sunnyvale, CA, USA) using the RNA Master Hybridisation Probes kit (Roche; Manheim, Germany). A mobile laboratory was used which consisted of a glovebox, a Diagnostics-in-a-Suitcase (DiaS), and a solar panel and power pack set. The RT-RPA was performed using a custom-made EBOV-specific exo RT kit with pellets containing optimized enzyme concentrations.

The EBOV-RT-RPA was evaluated in comparison to two real-time PCR assays. The prevalence of EBOV in the swabs tested was 12.9%. The day of death after onset of disease peaked at day 6 (range: 2 to14 days) in the group of 67 swab-positive deceased for whom disease symptoms were recorded. Of 928 post-mortem swabs, 120 tested positive, and the combined SE and EBOV-RT-RPA yielded a sensitivity and specificity of 100% in reference to one real-time RT-PCR assay. Another widely used real-time RT-PCR was much less sensitive than expected. Results were provided very fast within 30 to 60 minutes, and the field deployment of the mobile laboratory helped improve burial management and community engagement.

Related Links:

Institut Pasteur de Dakar  
Qiagen
Cepheid



Gold Member
Blood Gas Analyzer
Stat Profile pHOx
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Homocysteine Quality Control
Liquichek Homocysteine Control
Silver Member
PCR Plates
Diamond Shell PCR Plates
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Molecular Diagnostics

view channel
Image: LiDia-SEQ aims to deliver near-patient NGS testing capabilities to hospitals, labs and clinics (Photo courtesy of DNAe)

World's First NGS-Based Diagnostic Platform Fully Automates Sample-To-Result Process Within Single Device

Rapid point-of-need diagnostics are of critical need, especially in the areas of infectious disease and cancer testing and monitoring. Now, a direct-from-specimen platform that performs genomic analysis... Read more

Hematology

view channel
Image: Residual leukemia cells may predict long-term survival in acute myeloid leukemia (Photo courtesy of Shutterstock)

MRD Tests Could Predict Survival in Leukemia Patients

Acute myeloid leukemia is an aggressive blood cancer that disrupts normal blood cell production and often relapses even after intensive treatment. Clinicians currently lack early, reliable markers to predict... Read more

Pathology

view channel
Image: The AI tool advances precision diagnostics by linking genetic mutations directly to disease types (Photo courtesy of Shutterstock)

AI Tool Simultaneously Identifies Genetic Mutations and Disease Type

Interpreting genetic test results remains a major challenge in modern medicine, particularly for rare and complex diseases. While existing tools can indicate whether a genetic mutation is harmful, they... Read more
Copyright © 2000-2025 Globetech Media. All rights reserved.