Autosomal Dominant Disorder Confirmed by Biomarker Assay

By LabMedica International staff writers
Posted on 06 Feb 2012
The erythrocyte glucose-uptake assay has been used to confirm the diagnosis of glucose transporter type 1 deficiency syndrome (Glut1-DS). More...


The disease is diagnosed with cerebrospinal fluid (CSF) glucose values of less than 2.2 mmol/L, or lowered CSF/plasma glucose ratio of less than 0.4, and the erythrocyte 3-O-methyl-d-glucose uptake assay (3-OMG).

Scientists at Columbia University (New York, NY, USA) studied 109 suspected cases of Glut-1 DS, all who had a consistent clinical picture and a low CSF glucose concentration (hypoglycorrhachia). To confirm the diagnosis of Glut1 DS, blood samples from both patients and parents were analyzed using the erythrocyte 3-OMG uptake assay. The erythrocytes are radioactively labeled and measured on a scintillation counter.

Copy number analysis was performed via single nucleotide polymorphism (SNP) oligonucleotide microarray analysis (SOMA) using the Affymetrix Genome Wide Human SNP Array 6.0 (Santa Clara, CA, USA), which includes over 906,600 SNPs and more than 946,000 probes for the detection of copy number variation. A multiplex ligation-dependent probe amplification (MLPA) kit (MRC-Holland; Amsterdam, Netherlands) was used to screen eight patients with decreased 3-OMG uptake without identified sequence based mutations or deletions using SOMA. .

The uptake assay was decreased in 74 cases (group 1) and normal in 35 cases (group 2). The disease-causing mutations were identified in 70 group 1 patients (95%) and only one in group 2 patients (3%). The cut-off for an abnormally low uptake value was increased from 60% to 74% with a corresponding sensitivity of 99% and specificity of 100%. The correlation between the uptake values for the time-curve and the kinetic concentration curve were strongly positive. There was a significant correlation between the mean erythrocyte 3-OMG uptake and clinical severity.

The authors concluded that the erythrocyte glucose-uptake assay, when abnormal, essentially confirms the clinical suspicion of Glut1 DS. Furthermore, the degree of uptake abnormality correlates with glucose transport functional activity and has implications regarding clinical severity and prognosis. Glut1 deficiency syndrome is characterized classically by infantile onset seizures, delayed neurological development, disorders of movement, and acquired microcephaly. The study was published in December 2011, in the Annals of Neurology.

Related Links:

Columbia University
Affymetrix
MRC-Holland



Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Nucleic Acid Extractor System
NEOS-96 XT
New
Gold Member
Serum Indices Control
Acusera Serum Indices Control
New
Automated Immunoassay Analyzer
SuperFlex™
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Microbiology

view channel
Image Credit: 123RF

FDA-Cleared Multiplex PCR Test Detects 13 Respiratory Pathogens in a Single Sample

Respiratory tract infections can be difficult to distinguish at presentation because many cause overlapping, nonspecific symptoms and are initially grouped as influenza-like illnesses. Causes span a range... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image

Collaboration Combines AI Cognitive Assessment and RNA Blood Testing for Earlier Alzheimer’s Detection

Alzheimer’s disease is often identified only after substantial neurodegeneration, partly because current diagnostic pathways are fragmented and difficult to scale. As treatment shifts toward earlier intervention,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.