Features Partner Sites Information LinkXpress hp
Sign In
Advertise with Us
Sekisui Diagnostics

Download Mobile App




Preoperative Bacteriuria Unconnected to Joint Infection

By LabMedica International staff writers
Posted on 22 Aug 2017
Patients who undergo elective joint replacement are traditionally screened and treated for preoperative bacteriuria in order to prevent periprosthetic joint infection (PJI), but more recently, this practice has been questioned.

Periprosthetic joint infection (PJI) is one of the most challenging and frequent complications after lower-extremity joint (hip and knee) arthroplasty. More...
However, there is no single accepted set of diagnostic criteria for PJI. Various definitions have been proposed; however, none have been widely adopted.

A team of scientists at Tampere University Hospital (Tampere, Finland) identified patients between September 2002 and December 2013 who had undergone a primary hip or knee replacement in a tertiary care hospital from the hospital database that included 23,171 joint replacements, 10, 200 hips, and 12,971 knees. Patients with subsequent PJI or superficial wound infection in a one-year follow-up period were identified based on prospective infection surveillance. The association between bacteriuria and PJI was examined using a multivariable logistic regression model.

The team found the incidence of PJI was 0.68%, a total of 158 patients. Preoperative bacteriuria was not associated with an increased risk of PJI either in the univariate 0.51% versus. 0.71%; Odds ratio (OR) = 0.72, (95% confidence interval (CI) 0.34 – 1.54) or in the multivariable the OR = 0.82, (95% CI 0.38 – 1.77) analysis. There were no cases where PJI was caused by a pathogen identified in the preoperative urine culture. Results were similar for superficial infections.

The authors concluded that there was no association between preoperative bacteriuria and postoperative surgical site infection. Based on these results, it seems that the preoperative screening and treatment of asymptomatic bacteriuria is not required. The study was published on July 28, 2017, in the journal Clinical Microbiology and Infection.

Related Links:
Tampere University Hospital


Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
NEW PRODUCT : SILICONE WASHING MACHINE TRAY COVER WITH VICOLAB SILICONE NET VICOLAB®
REGISTRED 682.9
LAIR2 Antibody Pair Set
LAIR2 Antibody Pair [Biotin]
New
Automated Immunoassay Analyzer
SuperFlex™
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image Credit: 123RF

Screening After Pneumococcal Disease May Reveal Undiagnosed Blood Cancer or Immune Disorders

Severe pneumococcal disease requiring hospitalization often presents as pneumonia, particularly in older adults and people with cancer or compromised immune function. Because M protein testing and antibody... Read more

Microbiology

view channel
Image Credit: 123RF

FDA-Cleared Multiplex PCR Test Detects 13 Respiratory Pathogens in a Single Sample

Respiratory tract infections can be difficult to distinguish at presentation because many cause overlapping, nonspecific symptoms and are initially grouped as influenza-like illnesses. Causes span a range... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image

Collaboration Combines AI Cognitive Assessment and RNA Blood Testing for Earlier Alzheimer’s Detection

Alzheimer’s disease is often identified only after substantial neurodegeneration, partly because current diagnostic pathways are fragmented and difficult to scale. As treatment shifts toward earlier intervention,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.