Automatic Blood Cell Analyzer Detects Malaria Parasites

By LabMedica International staff writers
Posted on 15 Dec 2011
An automated hematology analyzer can detect malaria parasites during routine complete blood counts.

The analyzer can sensitively detect and accurately monitor an infection of Plasmodium vivax in blood samples, as well as being an effective screening test for the parasite.

Scientists at the Catholic University of Korea (Seoul, Korea) retrospectively analyzed a total of 1,761 complete blood count (CBC) samples generated by the automated hematology analyzer. More...
The sample pool contained 123 samples from 52 P. vivax malaria patients and 1,504 nonmalarial samples including 509 patients with leucopenia whose white blood cell count was less than 2,000/μL, and 134 normal subjects.

The P. vivax malaria samples exhibited easily recognizable typical malaria signals on the nucleated red blood cell (nRBC) plots with a sensitivity of 100% using the automatic blood cell analyzer, the DxH 800. All 1,504 samples without P. vivax infection were negative for malaria signal giving a specificity of 100%. The size of P. vivax malaria signals correlated approximately with the parasite burden.

The gold standard of P. vivax-malaria diagnosis is the microscopy of blood smears. Although microscopy is a rapid, cost-effective, and readily applicable method, it has many disadvantages, including low sensitivity, specificity, and precision. Therefore, there is a clear need for an effective screening test for P. vivax-malaria detection in both high-prevalence areas and developed countries.

The automated hematology analyzer DxH 800 (Beckman Coulter Inc., Miami, FL, USA) provided very sensitive and specific, easily recognizable P. vivax-malaria signals on routine CBC without need for the additional reagents or special procedures. The study was published online on November 11, 2011, in the International Journal of Laboratory Hematology.

Related Links:
Catholic University of Korea
Beckman Coulter Inc.




Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
NEW PRODUCT : SILICONE WASHING MACHINE TRAY COVER WITH VICOLAB SILICONE NET VICOLAB®
REGISTRED 682.9
HPV Test
Allplex HPV28 Detection
Automated Clinical Chemistry Analyzer
Envoy 500+
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image Credit: 123RF

Screening After Pneumococcal Disease May Reveal Undiagnosed Blood Cancer or Immune Disorders

Severe pneumococcal disease requiring hospitalization often presents as pneumonia, particularly in older adults and people with cancer or compromised immune function. Because M protein testing and antibody... Read more

Microbiology

view channel
Image Credit: 123RF

FDA-Cleared Multiplex PCR Test Detects 13 Respiratory Pathogens in a Single Sample

Respiratory tract infections can be difficult to distinguish at presentation because many cause overlapping, nonspecific symptoms and are initially grouped as influenza-like illnesses. Causes span a range... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image

Collaboration Combines AI Cognitive Assessment and RNA Blood Testing for Earlier Alzheimer’s Detection

Alzheimer’s disease is often identified only after substantial neurodegeneration, partly because current diagnostic pathways are fragmented and difficult to scale. As treatment shifts toward earlier intervention,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.