A fully automated, standardized direct biomarker panel offers clinicians a quick, reliable, minimally invasive blood test option to assess liver fibrosis–a leading indicator of chronic liver disease (CLD).

The Enhanced Liver Fibrosis (ELF) test is a simple, standardized blood test that assesses the severity of liver fibrosis by combining three direct serum biomarkers—hyaluronic acid (HA), procollagen III amino terminal peptide (PIIINP), and tissue inhibitor of metalloproteinase 1 (TIMP-1)—in an algorithm. More...
The result is an ELF score, which correlates to the level of liver fibrosis assessed by liver biopsy, the current standard of care for liver fibrosis diagnosis. The ELF test has been CE-marked for use on the ADVIA Centaur immunoassay systems. Results are available in 60 minutes.

The ELF test has been clinically validated on an Immuno-1 autoanalyzer in an international multicenter study with a mix of patient groups, including viral hepatitis, nonalcoholic fatty liver disease (NAFLD), and alcoholic patient groups. Additionally, a 7-year follow-up study involving over 450 patients has shown that the ELF markers are at least comparable to liver histology at predicting clinical outcomes of CLD.

With the addition of its ELF test, Siemens Healthcare Diagnostics (Tarrytown, NY, USA) offers an integrated portfolio of diagnostic solutions for managing liver health, which includes routine chemistry tests, hepatitis serology tests, viral load testing, and ultrasound systems.

"The discovery of the ELF markers represents a significant advance in the diagnosis of patients with liver disease," said William Rosenberg, MBBS, D. Phil, Peter Scheuer, chair in liver diseases, joint director of the Center for Hepatology University College London, (United Kingdom), said, "Of particular benefit, the ELF test can help to identify patients with mild-to-moderate liver fibrosis, which is usually asymptomatic, so that clinicians are able to intervene before significant damage to the liver occurs."

Related Links:

Siemens Healthcare Diagnostics
Center for Hepatology University College London
Siemens ELF Test



Platinum Member
Automated Coagulation Analyzer
Hemolumi H6
Gold Member
Quantitative POC Immunoassay Analyzer
EASY READER+
New
MR-proADM Test
B•R•A•H•M•S MR-proADM KRYPTOR test
Thyroid Test
Anti-Thyroid EIA Test
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Microbiology

view channel
Image Credit: 123RF

FDA-Cleared Multiplex PCR Test Detects 13 Respiratory Pathogens in a Single Sample

Respiratory tract infections can be difficult to distinguish at presentation because many cause overlapping, nonspecific symptoms and are initially grouped as influenza-like illnesses. Causes span a range... Read more

Technology

view channel
Image: The laser-based photoacoustic spectroscopy setup consists of a Mid-IR laser equipped with three QCL modules covering wavelengths from 5.6 μm to 12.9 μm, two silver coated mirrors (SCM), a dichroic mirror (DM) with a transmittance of 90%, a thermal power sensor head (PM) to monitor the output laser power, a mechanical chopper (MC) for frequency modulation and a CEPAS-detector with a self-designed swab holder (SH). (Credit: Graunke, T., Scholz, T., Pieniak, M. et al. Scientific Reports (2026). https://doi.org/10.1038/s41598-026-68298-9)

Laser-Based Swab Analysis Shows Promise for Detecting Disease-Linked Odor Patterns

Disease-related changes in volatile organic compounds can alter body odor, producing measurable patterns in exhaled breath and bodily fluids. Current analytical methods can be complex, time-consuming,... Read more

Industry

view channel
Image

Collaboration Combines AI Cognitive Assessment and RNA Blood Testing for Earlier Alzheimer’s Detection

Alzheimer’s disease is often identified only after substantial neurodegeneration, partly because current diagnostic pathways are fragmented and difficult to scale. As treatment shifts toward earlier intervention,... Read more
Copyright © 2000-2026 Globetech Media. All rights reserved.